Asset ID: |
1-72-2403221.1 |
Update Date: | 2018-05-25 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2403221.1
:
T10000D - FSC 3F31 SNO - File Protect Sensor Failure
Related Items |
- StorageTek T10000D Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
|
In this Document
Applies to:
StorageTek T10000D Tape Drive - Version All Versions and later
Information in this document applies to any platform.
Symptoms
The host application detects that one or more tapes are in write protected status on a certain drive. This goes undetected in the drive.
Cause
The file protect sensor in the drive could fail and the drive would not detect a problem.
Solution
A microcode change was added to T10000D microcode release 4.14.102 to test the file protect sensor after each tape is unloaded. If the test fails, the drive will SNO with FSC 3F31 and further tape mounts are prohibited. The drive needs to be replaced.
Attachments
This solution has no attachment