Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2403221.1
Update Date:2018-05-25
Keywords:

Solution Type  Problem Resolution Sure

Solution  2403221.1 :   T10000D - FSC 3F31 SNO - File Protect Sensor Failure  


Related Items
  • StorageTek T10000D Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

StorageTek T10000D Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

The host application detects that one or more tapes are in write protected status on a certain drive. This goes undetected in the drive.

Cause

The file protect sensor in the drive could fail and the drive would not detect a problem.

Solution

 A microcode change was added to T10000D microcode release 4.14.102 to test the file protect sensor after each tape is unloaded. If the test fails, the drive will SNO with FSC 3F31 and further tape mounts are prohibited. The drive needs to be replaced.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.