IBM LTO5 - Tape Drive Intermittently Goes Offline From Tape Mover Perspective
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
|
In this Document
Created from <SR 3-17500886181>
Applies to:
IBM LTO5 Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
Error code " 6"
Cause
Media UG****L5 encountered the error code " 6" multiple times
1 212811992 9 6: Drive or Media UG****L5
2 212813270 8 6: Drive or Media UG****L5
3 212813942 7 6: Drive or Media UG****L5
4 212814942 6 6: Drive or Media UG****L5
5 212815814 5 6: Drive or Media UG****L5
6 212816362 4 6: Drive or Media UG****L5
7 212816981 3 6: Drive or Media UG****L5
8 212817525 2 6: Drive or Media UG****L5
9 212817889 1 6: Drive or Media UG****L5
Solution
Inspect the tape and if issues are observed, copy the data then remove the tape from the service.