Solution Type  Problem Resolution Sure

Solution  2401223.1 :   IBM LTO5 - Tape Drive Intermittently Goes Offline From Tape Mover Perspective  


Related Items
  • IBM LTO5 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-17500886181>

Applies to:

IBM LTO5 Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Error code " 6"

Cause

Media UG****L5 encountered the error code " 6" multiple times
 
1 212811992 9 6: Drive or Media UG****L5
2 212813270 8 6: Drive or Media UG****L5
3 212813942 7 6: Drive or Media UG****L5
4 212814942 6 6: Drive or Media UG****L5
5 212815814 5 6: Drive or Media UG****L5
6 212816362 4 6: Drive or Media UG****L5
7 212816981 3 6: Drive or Media UG****L5
8 212817525 2 6: Drive or Media UG****L5
9 212817889 1 6: Drive or Media UG****L5
 

Solution

Inspect the tape and if issues are observed, copy the data then remove the tape from the service.
 