Asset ID: |
1-72-2400769.1 |
Update Date: | 2018-05-18 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2400769.1
:
Cannot Start Or Connect To SEFOS on an ES2-64 Switch
Related Items |
- Oracle Ethernet Switch ES2-64
|
Related Categories |
- PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Ethernet Switches
|
In this Document
Created from <SR 3-17413887461>
Applies to:
Oracle Ethernet Switch ES2-64 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
Can not connect to sefos from the ES2 ILOM prompt.
ES2-> cd /SYS/fs_cli
Are you sure you want to start /SYS/fs_cli (y/n)? y
start: Connecting to Fabric SEwitch CLI
Sefos is not running, 3:Child PID 7529 exited with status 256
start: The session with /SYS/fs_cli has ended.
ES2-> start /SYS/sefos
Are you sure you want to start /SYS/sefos (y/n)? y
start: Please wait while sefos comes up, this can take anywhere from 30 seconds to 2 minutes depending on the conf
iguration
..................................................................................................................
..................................................................................................................
..........................................................................
start: Time Out: SEFOS failed to start. <----------------------------
ILOM Snapshot from ES2 messages file shows:
May 6 00:20:35 localhost kernel: pciehp 0000:00:1c.0:pcie04: Card not present on Slot(0)
May 6 00:20:37 localhost kernel: pciehp 0000:00:1c.0:pcie04: Card present on Slot(0)
May 6 00:20:37 localhost kernel: pciehp 0000:00:1c.0:pcie04: Link Training Error occurs
May 6 00:20:37 localhost kernel: pciehp 0000:00:1c.0:pcie04: Failed to check link status
May 6 00:20:37 localhost kernel: pciehp 0000:00:1c.0:pcie04: Card present on Slot(0)
May 6 00:20:37 localhost kernel: pciehp 0000:00:1c.0:pcie04: Link Training Error occurs
May 6 00:20:37 localhost kernel: pciehp 0000:00:1c.0:pcie04: Failed to check link status
Cause
This indicates that the switch chip will not initialize.
Solution
Remove AC power cords for 5 minutes and then power up and check if sefos will allow access.
If will not come up, then the next step is to replace the switch.
References
<NOTE:1540688.1> - Oracle 10-Gigabit Ethernet Switches Support
Attachments
This solution has no attachment