![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2399905.1 : Eagle: UAM 0522-Frame Power Usage Reached LVL1
In this Document
Created from <SR 3-17375804421> Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 46.3 and laterInformation in this document applies to any platform. SymptomsUAM 0522 - Frame power usage reached LVL1 ====================================================================== - - - Changes
CauseThe maximum calculated power for a frame is based on the cards that are populated in the system, and includes a fan tray assembly for every shelf (the system cannot detect the presence or absence of a fan tray, and assumes presence for the calculation). --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
eagle 18-04-27 10:35:27 GMT EAGLE 46.3.1.0.0-68.30.1 Power Threshold Power Consumption Frame (Amps) (Watts) (Amps) (Watts) ----- ----------------- ----------------- CF00 45 1800 35.70 1428 EF00 45 1800 34.00 1360 EF01 45 1800 33.66 1346 EF02 45 1800 35.20 1408 EF03 45 1800 42.49 1700 >>>>> The Power Threshold in Amps is Set to 45 and the EF03 power is reaching 42.49. --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Solution1. A lot of non-provisioned cards where inserted in frame EF03. It is advised to remove those cards from system. chg-frm-pwr: frm=ef03:thrshld=50
Attachments This solution has no attachment |
||||||||||||||||||
|