Symptoms
Cause
Solution


Created from <SR 3-17430169451>

Applies to:

StorageTek T10000C Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Display in mainframe TSO.

RTD reported ECAM ERROR CC=5 RC=108
RTD R52XXV0X reported CMD reject: 80484027000000202000 >>1717<< 000000000000000000000000CE0E652059780000

SL8500 logs is showing messages below:

2018-05-06T17:39:43.147, 2.3.2.1.4, root, hli0, move, 19095880, warn, 3992, "Warning from device", Data=!|CDATA|drive 2,3,2,1,4: rewindUnload Successful with unitCheck 3215 (cartLabel = XX5074T2)||

 

Cause

The customer mounted a volume with high density for T10000C.

FSC Dictionary Description:
MODEL = T10000C
FSC = 1717
(FSC Match Found in Rev. 3.65)
FSC: 1717 ASC_FSC_FORM_INCMP_WRT_INIT_SEL
MIM Code: NONE
FRU: STATUS ONLY CONF: 100%
Summary: |INCOMPATIBLE |TAPE/DRIVE |WRITE COMMAND |
Field Text:
Incompatible tape/drive format during initial selection tests for a write command.


FSC Dictionary Description:
MODEL = T10000C
FSC = 3215
(FSC Match Found in Rev. 3.65)
FSC: 3215 DC_FSC_READ_UNSUPPORTED_FORMAT
MIM Code: NONE
FRU: STATUS ONLY CONF: 100%
Summary: |INCOMPATIBLE |MEDIA | *** |
Field Text:
Command rejected because a High Density tape is loaded in a low density drive. A low density drive cannot read a high density written tape. Only writes starting at block id 0 are allowed.
 

Solution

The volume that customer mounted on the drive was a high density tape and the T10000C can't read or write high density tapes.

The customer needs to mount this volume in a T10000D drives.
 