![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2398926.1 : T10000C - FSC 1717, ASC_FSC_FORM_INCMP_WRT_INIT_SEL and FSC 3215, DC_FSC_READ_UNSUPPORTED_FORMAT
In this Document
Created from <SR 3-17430169451> Applies to:StorageTek T10000C Tape Drive - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsDisplay in mainframe TSO. RTD reported ECAM ERROR CC=5 RC=108 SL8500 logs is showing messages below: 2018-05-06T17:39:43.147, 2.3.2.1.4, root, hli0, move, 19095880, warn, 3992, "Warning from device", Data=!|CDATA|drive 2,3,2,1,4: rewindUnload Successful with unitCheck 3215 (cartLabel = XX5074T2)||
CauseThe customer mounted a volume with high density for T10000C. FSC Dictionary Description: SolutionThe volume that customer mounted on the drive was a high density tape and the T10000C can't read or write high density tapes. The customer needs to mount this volume in a T10000D drives. Attachments This solution has no attachment |
||||||||||||||||
|