![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2398649.1 : Diameter Signaling Router (DSR): After Switchover From Primary To DR-NOAM, SNMP Trapping Configuration Cannot Be Modified
In this Document
Created from <SR 3-17312082041> Applies to:Oracle Communications Diameter Signaling Router (DSR) - Version DSR 8.1.1 and laterTekelec SymptomsUnable to modify the SNMP configuration after doing a Manual Switchover from Primary Site to DR site ChangesManual Switchover from Primary Site to DR site CauseCurrent Primary NOAM's (previous DR NOAM ie Site2_A) SnmpCfg table content displays the clusterId of previous Active NOAM(current DR NOAM ie Site1_A)
[admusr@Site1_NOAM_A ~]$ iqt -L SnmpCfg [admusr@Site2_NOAM_A ~]$ iqt -L SnmpCfg
clusterId=00000 clusterId=00000 portNum=0 portNum=0 enableMgr[0]=Yes enableMgr[0]=Yes enableMgr[1]=Yes enableMgr[1]=Yes enableMgr[2]=Yes enableMgr[2]=Yes enableMgr[3]=Yes enableMgr[3]=Yes enableMgr[4]=No enableMgr[4]=No managers[0]=X.X.X.X:161 managers[0]=X.X.X.X:161 managers[1]=X.X.X.X:161 managers[1]=X.X.X.X:161 managers[2]=X.X.X.X managers[2]=X.X.X.X managers[3]=X.X.X.X managers[3]=X.X.X.X managers[4]=guiadmin managers[4]=guiadmin mode=V2Only mode=V2Only secMode=authPriv secMode=authPriv authType=SHA1 authType=SHA1 privType=AES privType=AES username= username= password= password= community=TKLCsnmpuser community=TKLCsnmpuser rwcommunity=TKLCsnmpuser rwcommunity=TKLCsnmpuser engineId= engineId= flags=S flags=S ================================= ================================= clusterId=A0400 clusterId=A0400 portNum=0 portNum=0 enableMgr[0]=Yes enableMgr[0]=Yes enableMgr[1]=Yes enableMgr[1]=Yes enableMgr[2]=Yes enableMgr[2]=Yes enableMgr[3]=Yes enableMgr[3]=Yes enableMgr[4]=No enableMgr[4]=No managers[0]=X.X.X.X:161 managers[0]=X.X.X.X:161 managers[1]=X.X.X.X:161 managers[1]=X.X.X.X:161 managers[2]=X.X.X.X managers[2]=X.X.X.X managers[3]=X.X.X.X managers[3]=X.X.X.X managers[4]=guiadmin managers[4]= mode=V2Only mode=V2Only secMode=authPriv secMode=authPriv authType=SHA1 authType=SHA1 privType=AES privType=AES username= username= password= password= community=TKLCsnmpuser community=TKLCsnmpuser rwcommunity=TKLCsnmpuser rwcommunity=TKLCsnmpuser engineId= engineId= flags=S flags=S
Server_ID NodeID ClusterID
0 Site1_NOAM_A A0400 1 Site1_NOAM_B A0400 2 Site2_NOAM_A A0450 3 Site2_NOAM_B A0450 SolutionBug 27984917 : "Unable to modify the SNMP config after doing a Manual SWO from P Site to DR site" is created for this issue References<BUG:27984917> - UNABLE TO MODIFY THE SNMP CONFIG AFTER DOING A MANUAL SWO FROM P SITE TO DR SITEAttachments This solution has no attachment |
||||||||||||||||||||
|