Created from <SR 3-17456538951> Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 46.5 and laterInformation in this document applies to any platform. SymptomsOn a particular linkset, what is happening is that SCTP assocs are ESTABLISHED, but find problems when we enable the signaling links in that linkset. > pass:cmd="linkinfo -l A8":loc=1204
18-05-11 12:19:16.560 M2PA_T2_EXPIRED 18-05-11 12:19:16.560 L2_L3_OUT_OF_SERVICE 18-05-11 12:19:16.560 M2PA_LSO_TRANSMITTED 18-05-11 12:19:16.560 LINK_STATE_CONNECTED 18-05-11 12:19:16.570 RETRIEVAL_COMPLETE 18-05-11 12:19:17.370 L3_L2_EMERGENCY 18-05-11 12:19:17.370 L3_L2_START 18-05-11 12:19:17.370 M2PA_LSA_TRANSMITTED 18-05-11 12:19:17.370 LINK_STATE_NOT_ALIGNED M2PA stops timer T2 when it has received the Link Status Alignment message from its peer. If timer T2 expires, then M2PA reports to MTP3 that the link is out of service. https://tools.ietf.org/html/draft-ietf-sigtran-m2pa-07 (Page 26) Changes
CauseIncorrect/ Incomplete configuration for links/route for the particular linkset is usually the cause. In this case, route configuration is not done for the particular linkset. > rept-stat-rte:dpci=x-xxx-x:mode=full
stphostname 18-05-11 12:27:27 GMT EAGLE 46.5.0.0.1-70.39.1 DPCI PST SST AST x-xxx-x OOS-MT Idle INACCESS ALARM STATUS = No Alarms. RTE COST LSN APC LS STAT NON-ADJ ROUTE STAT 1 -- ---------- ---***-***-*** -------- -------- -------- 2 -- ---------- ---***-***-*** -------- -------- -------- 3 -- ---------- ---***-***-*** -------- -------- -------- 4 -- ---------- ---***-***-*** -------- -------- -------- 5 -- ---------- ---***-***-*** -------- -------- -------- 6 -- ---------- ---***-***-*** -------- -------- -------- SolutionAdd the particular linkset in the route configuration (ent-rte) and enable the links from both ends.