Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2398617.1
Update Date:2018-05-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  2398617.1 :   In a particular linkset, SLKs are down while Associations are established  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-17456538951>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 46.5 and later
Information in this document applies to any platform.

Symptoms

On a particular linkset, what is happening is that SCTP assocs are ESTABLISHED, but find problems when we enable the signaling links in that linkset.

> pass:cmd="linkinfo -l A8":loc=1204

    18-05-11 12:19:16.560 M2PA_T2_EXPIRED               
    18-05-11 12:19:16.560 L2_L3_OUT_OF_SERVICE          
    18-05-11 12:19:16.560 M2PA_LSO_TRANSMITTED          
    18-05-11 12:19:16.560 LINK_STATE_CONNECTED          
    18-05-11 12:19:16.570 RETRIEVAL_COMPLETE            
    18-05-11 12:19:17.370 L3_L2_EMERGENCY               
    18-05-11 12:19:17.370 L3_L2_START                   
    18-05-11 12:19:17.370 M2PA_LSA_TRANSMITTED          
    18-05-11 12:19:17.370 LINK_STATE_NOT_ALIGNED
M2PA stops timer T2 when it has received the Link Status Alignment message from its peer. If timer T2 expires, then M2PA reports to MTP3 that the link is out of service.
https://tools.ietf.org/html/draft-ietf-sigtran-m2pa-07 (Page 26)

Changes

 

Cause

Incorrect/ Incomplete configuration for links/route for the particular linkset is usually the cause.

In this case, route configuration is not done for the particular linkset.

> rept-stat-rte:dpci=x-xxx-x:mode=full

  stphostname 18-05-11 12:27:27 GMT EAGLE 46.5.0.0.1-70.39.1
  DPCI PST SST AST
  x-xxx-x OOS-MT Idle INACCESS
  ALARM STATUS = No Alarms.
  RTE COST LSN APC LS STAT NON-ADJ ROUTE STAT
  1 -- ---------- ---***-***-*** -------- -------- --------
  2 -- ---------- ---***-***-*** -------- -------- --------
  3 -- ---------- ---***-***-*** -------- -------- --------
  4 -- ---------- ---***-***-*** -------- -------- --------
  5 -- ---------- ---***-***-*** -------- -------- --------
  6 -- ---------- ---***-***-*** -------- -------- --------

Solution

Add the particular linkset in the route configuration (ent-rte) and enable the links from both ends.
 

 