Asset ID: |
1-72-2397750.1 |
Update Date: | 2018-05-14 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2397750.1
:
IBM LTO4 - Drive has Uncorrectable Errors on Multiple Cartridges
Related Items |
- Sun StorageTek SL8500 Modular Library System
- IBM LTO4 Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-17353899676>
Applies to:
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
IBM LTO4 Tape Drive - Version All Versions and later
Information in this document applies to any platform.
Symptoms
The drive has Uncorrectable Errors on multiple cartridges.
6017: FsczzERRMAP_DRH_FSC_AYAME_CDSC_RESERVE_ERROR
CDSC dataflow block detects a reserved control code.
7060: FsczzERRMAP_MED_C2_UNCORRECTABLE
Data correction problem (detected by dataflow and microcode)
0 0000: No Error Detected FUJIFILM 39T5YC0G B5JF (df110518o) 4810: Needs Clean due to Usage FFh 00 00 00 00 00 00 00 00 0 19 C: Clean Required 551040365 286d 10h:57m:11s R11162L4 0
1 7060: C2 Uncorrectable Error FUJIFILM 4LAK02WR B5JF (df110518o) 7060: C2 Uncorrectable Error 0Ch 21 00 00 1b 32 92 0f b0 101 19 6: Drive or Media 181985092 287d 19h:18m:01s R11418L4 46
2 7013h SONY 01207336 B5JF (df110518o) 7060: C2 Uncorrectable Error 0Fh 21 00 00 1b 32 92 f0 af 96 19 6: Drive or Media 584225091 289d 00h:51m:41s R11681L4 55
3 7060: C2 Uncorrectable Error FUJIFILM 88TFCG74 B5JF (df110518o) 7060: C2 Uncorrectable Error 0Dh 21 00 00 1b 32 91 10 90 75 20 6: Drive or Media 256435880 0d 17h:14m:10s R08446L4 6
4 7060: C2 Uncorrectable Error FUJIFILM 88TFCG74 B5JF (df110518o) 7060: C2 Uncorrectable Error 0Dh 21 00 00 1b 32 91 10 90 1 20 6: Drive or Media 284981820 0d 18h:02m:11s R08446L4 8
5 0000: No Error Detected FUJIFILM 88TFCG74 B5JF (df110518o) 6017: Ayame CDSC Reserve Error 0Ch 21 00 00 1b 32 92 0f b0 86 20 4: Firmware or Drive 872168971 1d 01h:24m:53s R08446L4 19
6 0000: No Error Detected SONY 91022306 B5JF (df110518o) 4810: Needs Clean due to Usage FFh 00 00 00 00 00 00 00 00 0 21 C: Clean Required 546504607 0d 09h:07m:15s R09848L4 0
7 7068h FUJIFILM C6T33TG1 B5JF (df110518o) 7068h 10h 21 00 00 1b 32 92 f0 af 114 21 6: Drive or Media 962713576 0d 23h:08m:28s R11135L4 22
8 0000: No Error Detected FUJIFILM 179RLWFA B5JF (df110518o) 6017: Ayame CDSC Reserve Error 10h 21 00 00 1b 32 92 f0 af 122 21 4: Firmware or Drive 703045697 1d 17h:36m:13s R10380L4 41
9 0000: No Error Detected FUJIFILM 179RLWFA B5JF (df110518o) 6017: Ayame CDSC Reserve Error 0Ch 21 00 00 1b 32 92 0f b0 31 22 4: Firmware or Drive 016422545 0d 01h:17m:46s R10380L4 40
Changes
Cause
Drive has worn out.
Solution
Replace the drive.
Attachments
This solution has no attachment