Solution Type  Problem Resolution Sure

Solution  2396141.1 :   Correctable ECC Memory Error on APPB Server  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS ELAP LSMS
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-17267671711>

Applies to:

Oracle Communications EAGLE (Hardware) - Version ELAP 10.0 and later
Information in this document applies to any platform.

Symptoms

Correctable ECC error on APPB server (Applies to ELAP, EPAP and LSMS servers on APPB hardware)

Changes

 

Cause

Memory bit read/write error
Possible memory DIMM issue

Solution

Perform the following steps to clear ecc logs

cd  /var/TKLC/log/ecc

mv  ecc.log  orig.ecc.log.bak

service syscheck stop

service syscheck start

syscheck

 

If alarm persists, power cycling the server using LOCK switch