Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2395532.1
Update Date:2018-05-10
Keywords:

Solution Type  Problem Resolution Sure

Solution  2395532.1 :   IBM LTO8 - Firmware Upgrades Fail Due to the Following Statement: Firmware File No Good  


Related Items
  • IBM LTO8 Tape Drive
  •  
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-17331292301>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
IBM LTO8 Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

The firmware upgrades fail due to the following statement: Firmware file no good.

Cause

Customer is attempting to upgrade code G9Q3 to the tape drives.

Attempting to load LTO6 code into LTO8 drives.

Solution

Load the correct code into the tape drives.

Product Family Library Firmware Library Patch Drive Supplier Drive Firmware Drive Patch
LTO-8HH (FC) 3.20 26359132 IBM HB83 27333574
LTO-8HH (SAS) 3.20 26359132 IBM HB83 27333591


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.