Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2395043.1
Update Date:2018-05-10
Keywords:

Solution Type  Problem Resolution Sure

Solution  2395043.1 :   Both Fans Showed Failed On OKM T7-1 Server  


Related Items
  • AD SaaS SL150 Backup LS Rack
  •  
  • Oracle Key Manager
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-17379978171>

Applies to:

AD SaaS SL150 Backup LS Rack - Version All Versions to All Versions [Release All Releases]
Oracle Key Manager - Version 3.0 and later
Sun SPARC Sun OS

Symptoms

Fan failures on OKM T7-1 server.

Changes

 

Cause

The fans are fine, the System FW: 9.7.5.b has bug 25464520 - Incorrect FM1 rear fan RPM reading.
 
System FW: 9.7.5.b has bug 25464520 - Incorrect FM1 rear fan RPM reading.
 

Solution

Upgrade System FW: 9.8.5.a 
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.