Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2394630.1
Update Date:2018-05-07
Keywords:

Solution Type  Problem Resolution Sure

Solution  2394630.1 :   DSR Line Protocol on Interface GigabitEthernet is Down  


Related Items
  • BNS Platform Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  




In this Document
Symptoms
Changes
Cause
Solution
 Perform following steps:
References


Created from <SR 3-15900213691>

Applies to:

BNS Platform Hardware - Version DSR 5.0 and later
Tekelec

Symptoms

Show Tech on the switch Shows following messages:
Oct 24 06:54:56.713: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to up
Oct 24 06:55:27.508: %LINK-3-UPDOWN: Interface GigabitEthernet0/3, changed state to down
Oct 24 06:55:29.547: %LINK-3-UPDOWN: Interface GigabitEthernet0/3, changed state to up
Oct 24 06:55:45.955: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to down
Oct 24 06:55:48.069: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to up
Oct 24 06:56:08.629: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to down
Oct 24 06:56:13.151: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to up
Oct 24 06:56:28.553: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to down
Oct 24 06:56:31.036: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to up
Oct 24 06:56:48.274: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to down
Oct 24 06:56:50.749: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to up
Oct 25 01:35:12.986: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to down
Oct 25 01:35:14.991: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to up
Oct 26 03:46:23.193: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to down

Changes

 

Cause

This is a hardware issue with either blade or the switch
 

Solution

Show Tech on the switch Shows following messages:

Oct 24 06:54:56.713: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to up
Oct 24 06:55:27.508: %LINK-3-UPDOWN: Interface GigabitEthernet0/3, changed state to down
Oct 24 06:55:29.547: %LINK-3-UPDOWN: Interface GigabitEthernet0/3, changed state to up
Oct 24 06:55:45.955: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to down
Oct 24 06:55:48.069: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to up
Oct 24 06:56:08.629: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to down
Oct 24 06:56:13.151: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to up
Oct 24 06:56:28.553: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to down
Oct 24 06:56:31.036: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to up
Oct 24 06:56:48.274: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to down
Oct 24 06:56:50.749: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to up
Oct 25 01:35:12.986: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to down
Oct 25 01:35:14.991: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to up
Oct 26 03:46:23.193: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/3, changed state to down

The switch is showing some errors for port 0/3 where the blade connects.

It is registering "symbol error frames" which usually is indicative of a hardware issue.

Since the switch only shows 1 reset for that port, it would appear that the issue is on the blade.

Perform following steps:

Move the blade to a different slot and see if the problem follows the blade to a new slot.
Clear the counters on both switch ports (0/3, and whatever port corresponds to the slot it moves in to)
To clear the counters:

  1. log into the console of the switch
  2. go into enable mode.
  3. Run following command: 
clear ip counters gigabit 0/3

If the problem moves with the blade, then blade will need to be replaced. Else it would be the switch that may have a bad port and would need to be replaced. 

 

References

<NOTE:2160456.1> - SRDC - Collect Data for Diameter Signaling Router

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback