Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2394501.1
Update Date:2018-05-10
Keywords:

Solution Type  Problem Resolution Sure

Solution  2394501.1 :   T10000C - FSC: 495D SI_FSC_UNDEFERRED_LOCATE_WHILE_MOVING  


Related Items
  • StorageTek T10000C Tape Drive
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-17407792359>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]
StorageTek T10000C Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

*** Alarm Description ***
FSC(1320): Drive communication time-out 1,2,2,1,4
Suspected Device Address :1.2.2.1.4
"Drive communication time-out 1,2,2,1,4"
Device Dmod: 516000201xxx
Tray SN: 516000201xxx
Device Model: SL8500

T10000C firmware installed 3.63.101

Changes

 

Cause

Automatic DUMP
 
Summary

Drive Microcode at time of dump: 3.63.101
Interface Type: FICON
Drive SNO FSC is 495d
(FSC Exact Match Found)
FSC: 495D SI_FSC_UNDEFERRED_LOCATE_WHILE_MOVING
MIM Code: INOPERABLE
FRU: MICROCODE CONF: 100%
Summary: |INVALID UCODE |INVALID STATE | *** |
Field Text:
A motion command was issued to the servo with the tape already in
motion.
 

Solution

The FIX of the DUMP 495d is in firmware 3.65.103.

Recommended to customer, firmware upgrade.

 

 

 

References