Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2393756.1
Update Date:2018-05-13
Keywords:

Solution Type  Problem Resolution Sure

Solution  2393756.1 :   Get SNMP Function On STP  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-17270910161>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 45.0 to EAGLE 46.6 [Release EAGLE 45.0 to EAGLE 46.0]
Information in this document applies to any platform.

Symptoms

On : EAGLE 46.2 version, Eagle 5 - STP (Production)

Problem details:

===========

Alarms are not Re-sync when NMS initiate the request.

Changes

 

Cause

NMS is sending GET function for alarm resync start request.  Eagle supports limited GET function to determine ONLY the status of the resync.
 

Solution

Currently Only SET function is supported for starting/stopping the resyncs from NMS


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback