![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2393382.1 : EAGLE : Unable to Delete IPSM CardConfigured for SFLOG
In this Document
Created from <SR 3-17384077971> Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 46.3 and laterTekelec SymptomsUnable to delete IPSM card configured for SFLOG. Changes
CauseSFLOG actionid "copymsu" was referenced to action set name "copymsu" > rtrv-gttact:actid=copymsu
Command Accepted - Processing tekelecstp 18-04-28 23:12:06 IST EAGLE 46.3.0.0.1-68.27.0 rtrv-gttact:actid=copymsu Command entered at terminal #8. ; tekelecstp 18-04-28 23:12:06 IST EAGLE 46.3.0.0.1-68.27.0 ACTID ACTION ATCAPERR ITCAPERR UDTSERR UIMREQD --------------------------------------------------------- ACTID ACTION PCA RI SSN MRNSET MAPSET ----------------------------------------------------------------------- ACTID ACTION PCI RI SSN MRNSET MAPSET ----------------------------------------------------------------------- ACTID ACTION PCN RI SSN MRNSET MAPSET ----------------------------------------------------------------------- ACTID ACTION PCN24 RI SSN MRNSET MAPSET ----------------------------------------------------------------------- ACTID ACTION PCN16 RI SSN MRNSET MAPSET ----------------------------------------------------------------------- ACTID ACTION THRESHOLD BURSTS DEFACTID ---------------------------------------------------------------- ACTID ACTION
---------------------------------------------------------------- copymsu sflog GTT-ACT table is (1 of 2000) 1% full. ; > rtrv-gttaset
Command Accepted - Processing tekelecstp 18-04-28 23:19:28 IST EAGLE 46.3.0.0.1-68.27.0 rtrv-gttaset Command entered at terminal #8. ; tekelecstp 18-04-28 23:19:28 IST EAGLE 46.3.0.0.1-68.27.0 ACTSN TEST ActIds
MODE ------------------------------- copymsu off copymsu (SFLOG),------,------, ------,------,------ GTT-ASET table is (1 of 20000) 1% full. ;
> dlt-card:loc=1112
E3275 Cmd Rej: SFLOG action is being referred by GTTACT Table
tekelecstp 18-04-28 23:11:49 IST EAGLE 46.3.0.0.1-68.27.0 dlt-card:loc=1112 Command entered at terminal #8. ; tekelecstp 18-04-28 23:11:49 IST EAGLE 46.3.0.0.1-68.27.0 DLT-CARD: MASP A - Command Aborted ;
> dlt-gttact:actid=copymsu
E5198 Cmd Rej: GTT Action entry is referenced
tekelecstp 18-04-28 23:12:56 IST EAGLE 46.3.0.0.1-68.27.0 dlt-gttact:actid=copymsu Command entered at terminal #8. ; tekelecstp 18-04-28 23:12:56 IST EAGLE 46.3.0.0.1-68.27.0 DLT-GTTACT: MASP A - Command Aborted ;
Solution1) Delete the SFLOG actionid "copy msu" referenced to action set "copymsu" > dlt-gttaset:actsn=copymsu Command Accepted - Processing tekelecstp 18-04-28 23:20:10 IST EAGLE 46.3.0.0.1-68.27.0 dlt-gttaset:actsn=copymsu Command entered at terminal #8. ; tekelecstp 18-04-28 23:20:10 IST EAGLE 46.3.0.0.1-68.27.0 GTT-ASET table is (0 of 20000) 0% full. ; tekelecstp 18-04-28 23:20:10 IST EAGLE 46.3.0.0.1-68.27.0 DLT-GTTASET: MASP A - COMPLTD ;
> dlt-gttact:actid=copymsu Command Accepted - Processing tekelecstp 18-04-28 23:20:39 IST EAGLE 46.3.0.0.1-68.27.0 dlt-gttact:actid=copymsu Command entered at terminal #8. ; tekelecstp 18-04-28 23:20:39 IST EAGLE 46.3.0.0.1-68.27.0 GTT-ACT table is (0 of 2000) 0% full. ; tekelecstp 18-04-28 23:20:40 IST EAGLE 46.3.0.0.1-68.27.0 DLT-GTTACT: MASP A - COMPLTD ;
> dlt-card:loc=1112 Command Accepted - Processing tekelecstp 18-04-28 23:20:51 IST EAGLE 46.3.0.0.1-68.27.0 dlt-card:loc=1112 Command entered at terminal #8. ; tekelecstp 18-04-28 23:20:51 IST EAGLE 46.3.0.0.1-68.27.0 0957.0500 CARD 1112 IPS Alarm for this entity is being cleared ; tekelecstp 18-04-28 23:20:52 IST EAGLE 46.3.0.0.1-68.27.0 DLT-CARD: MASP A - COMPLTD