Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2393382.1
Update Date:2018-05-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  2393382.1 :   EAGLE : Unable to Delete IPSM CardConfigured for SFLOG  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-17384077971>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 46.3 and later
Tekelec

Symptoms

Unable to delete IPSM card configured for SFLOG.

Changes

 

Cause

SFLOG actionid "copymsu" was referenced to action set name "copymsu"

> rtrv-gttact:actid=copymsu



Command Accepted - Processing


  tekelecstp 18-04-28 23:12:06 IST EAGLE 46.3.0.0.1-68.27.0

  rtrv-gttact:actid=copymsu

  Command entered at terminal #8.

;


  tekelecstp 18-04-28 23:12:06 IST EAGLE 46.3.0.0.1-68.27.0


  ACTID ACTION ATCAPERR ITCAPERR UDTSERR UIMREQD

  ---------------------------------------------------------

  ACTID ACTION PCA RI SSN MRNSET MAPSET

  -----------------------------------------------------------------------

  ACTID ACTION PCI RI SSN MRNSET MAPSET

  -----------------------------------------------------------------------

  ACTID ACTION PCN RI SSN MRNSET MAPSET

  -----------------------------------------------------------------------


  ACTID ACTION PCN24 RI SSN MRNSET MAPSET

  -----------------------------------------------------------------------


  ACTID ACTION PCN16 RI SSN MRNSET MAPSET

  -----------------------------------------------------------------------


  ACTID ACTION THRESHOLD BURSTS DEFACTID

  ----------------------------------------------------------------



   
 ACTID ACTION

  ----------------------------------------------------------------

  copymsu sflog

  

  GTT-ACT table is (1 of 2000) 1% full.



;



> rtrv-gttaset



Command Accepted - Processing


  tekelecstp 18-04-28 23:19:28 IST EAGLE 46.3.0.0.1-68.27.0

  rtrv-gttaset

  Command entered at terminal #8.

;



  tekelecstp 18-04-28 23:19:28 IST EAGLE 46.3.0.0.1-68.27.0



  ACTSN TEST ActIds

  MODE

  -------------------------------

  copymsu off copymsu (SFLOG),------,------,

  ------,------,------
  


  GTT-ASET table is (1 of 20000) 1% full.


;

 

> dlt-card:loc=1112


E3275 Cmd Rej: SFLOG action is being referred by GTTACT Table
  

 tekelecstp 18-04-28 23:11:49 IST EAGLE 46.3.0.0.1-68.27.0

  dlt-card:loc=1112

  Command entered at terminal #8.

;



  tekelecstp 18-04-28 23:11:49 IST EAGLE 46.3.0.0.1-68.27.0

  DLT-CARD: MASP A - Command Aborted

;

 

> dlt-gttact:actid=copymsu


E5198 Cmd Rej: GTT Action entry is referenced
  

  tekelecstp 18-04-28 23:12:56 IST EAGLE 46.3.0.0.1-68.27.0

  dlt-gttact:actid=copymsu

  Command entered at terminal #8.

;



  tekelecstp 18-04-28 23:12:56 IST EAGLE 46.3.0.0.1-68.27.0

  DLT-GTTACT: MASP A - Command Aborted

;

 

Solution

1) Delete the SFLOG actionid "copy msu" referenced to action set "copymsu"
2) Delete the SFLOG actionid "copy msu"
3) Delete the card
 

> dlt-gttaset:actsn=copymsu

Command Accepted - Processing

tekelecstp 18-04-28 23:20:10 IST EAGLE 46.3.0.0.1-68.27.0

dlt-gttaset:actsn=copymsu

Command entered at terminal #8.

;

tekelecstp 18-04-28 23:20:10 IST EAGLE 46.3.0.0.1-68.27.0

GTT-ASET table is (0 of 20000) 0% full.

;

tekelecstp 18-04-28 23:20:10 IST EAGLE 46.3.0.0.1-68.27.0

DLT-GTTASET: MASP A - COMPLTD

;

  

 

> dlt-gttact:actid=copymsu

Command Accepted - Processing

tekelecstp 18-04-28 23:20:39 IST EAGLE 46.3.0.0.1-68.27.0

dlt-gttact:actid=copymsu

Command entered at terminal #8.

;

tekelecstp 18-04-28 23:20:39 IST EAGLE 46.3.0.0.1-68.27.0

GTT-ACT table is (0 of 2000) 0% full.

;

tekelecstp 18-04-28 23:20:40 IST EAGLE 46.3.0.0.1-68.27.0

DLT-GTTACT: MASP A - COMPLTD

;

 

> dlt-card:loc=1112

Command Accepted - Processing

tekelecstp 18-04-28 23:20:51 IST EAGLE 46.3.0.0.1-68.27.0

dlt-card:loc=1112

Command entered at terminal #8.

;

tekelecstp 18-04-28 23:20:51 IST EAGLE 46.3.0.0.1-68.27.0

0957.0500 CARD 1112 IPS Alarm for this entity is being cleared

;

tekelecstp 18-04-28 23:20:52 IST EAGLE 46.3.0.0.1-68.27.0

DLT-CARD: MASP A - COMPLTD

  

 

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.