![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2392712.1 : SBC 4600: Diagnostic NIU Faulty : testAdamaPciInventory FAILED : [ERROR]: Function:DiagPciInventoryTest
In this Document
Created from <SR 3-17214201191> Applies to:Acme Packet 4600 - Version S-Cz7.3.0 and laterInformation in this document applies to any platform. SymptomsACME 4600 has bad PHY(NIU) board. The following error detected in Diagnostics Log. Changes
CauseComponent failure in NIU board. diag_fld > t*
testAdamaPegasusFpgaLatchStatus------------------------------------------>PASSED testAdamaPciInventory---------------------------------------------------->FAILED [DiagLog Start] [ERROR]: PID:2338 (22) Function:DiagPciInventoryTest 01:56:38 PM on 04/04/18 TEMP: 27 C Actual number of instances does not match expected: Device: Nitrox PX 1620 Possible Device ID's: { 0x0010 } Vendor ID: 177d Expected Number of Instances: 4 Actual Number of Instances: 3 Device BDF's that are present can be found in the DiagLog (info) [DiagLog End] <----------- TESTING HAS BEEN HALTED!! -----------> <------------------ TEST SUMMARY ------------------> testAdamaPegasusFpgaLatchStatus----------PASSED testAdamaPciInventory--------------------FAILED TEST SUITE FAILED RESETTING TEST STATUS! diag_fld > ***********************************
in mfg. diag mode **************************** diag_mfg > t* testAdamaPegasusFpgaLatchStatus------------------------------------------>PASSED testAdamaPciInventory---------------------------------------------------->FAILED [DiagLog Start] [ERROR]: PID:2341 (22) Function:DiagPciInventoryTest 02:04:00 PM on 04/04/18 TEMP: 26 C Actual number of instances does not match expected: Device: Nitrox PX 1620 Possible Device ID's: { 0x0010 } Vendor ID: 177d Expected Number of Instances: 4 Actual Number of Instances: 3 Device BDF's that are present can be found in the DiagLog (info) [DiagLog End] testAdamaPciLinkStatus--------------------------------------------------->PASSED testAdamaBootDeviceAttributes-------------------------------------------->PASSED testAdamaEusbFileSystem-------------------------------------------------->PASSED testAdamaPegasusFpgaAcess------------------------------------------------>PASSED testAdamaI2cMasterRegAddr------------------------------------------------>PASSED testAdamaI2cMasterRegData------------------------------------------------>PASSED testAdamaI2cMainMux------------------------------------------------------>PASSED testAdamaIdProm---------------------------------------------------------->PASSED testAdamaCpuTempSensors-------------------------------------------------->PASSED testAdamaTempSensors----------------------------------------------------->PASSED testAdamaPolRegulators--------------------------------------------------->PASSED testAdamaPhyHotswapStatus------------------------------------------------>PASSED testAdamaPlxEepromRevision----------------------------------------------->PASSED testAdamaI2cPex87XX------------------------------------------------------>PASSED testAdamaI2cSi5338c------------------------------------------------------>PASSED testAdamaFanId----------------------------------------------------------->PASSED
SolutionThe NIU board is faulty and requires a replacement. Attachments This solution has no attachment |
||||||||||||||||||
|