Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2391735.1
Update Date:2018-04-29
Keywords:

Solution Type  Problem Resolution Sure

Solution  2391735.1 :   bdacheckvnics and bdaibstatus Show Ports Are Not Able to Ping the Gateway From the Leaf  


Related Items
  • Big Data Appliance X6-2 Hardware
  •  
Related Categories
  • PLA-Support>Eng Systems>BDA>Big Data Appliance>DB: BDA_EST
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-17354164881>

Applies to:

Big Data Appliance X6-2 Hardware - Version All Versions and later
Linux x86-64

Symptoms

Both bdacheckvnics and bdaibstatus show that not all vnics can ping the gateway.  Output looks like below.  Note the last column should all report "yes".

# dcli "/opt/oracle/bda/network/bdacheckvnics -s | grep eth".
 
*.*.*.1: bdanode01 eth8 up no no sw-ib2 LAG-01 no N/A
*.*.*.1: bdanode01 eth9 up yes yes sw-ib3 LAG-01 yes N/A
*.*.*.2: bdanode02 eth8 up yes yes sw-ib2 LAG-01 yes N/A
*.*.*.2: bdanode02 eth9 up no no sw-ib3 LAG-01 no N/A

 

Cause

This is due to an internal but such that the bdachecknet utility is not properly testing the failover to the backup slave.

Bug 27269787 - bdachecknet not properly testing the failover to the backup slave
 
 

Solution

On BDA V4.11, apply Patch 27672443.
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback