![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2390835.1 : Oracle ZFS Storage Appliance: Node not booting. No display via serial connection to ILOM
In this Document
Created from <SR 3-16911325241> Applies to:Sun Storage 7410 Unified Storage System - Version All Versions and laterSun Storage 7310 Unified Storage System - Version All Versions and later Sun Storage 7210 Unified Storage System - Version All Versions and later Sun Storage 7110 Unified Storage System - Version All Versions and later Sun ZFS Storage 7420 - Version All Versions and later 7000 Appliance OS (Fishworks) SymptomsNode not booting Unable to access ILOM Amber led blinking on both power supplies. No display when connected direct monitor to server. All disk trays were receiving power.
ChangesSystem was not in use for a while. No known changes.
CauseMultiple hardware failures.
Solution1. Verify and confirm with customer that external Power Supply is working fine.
2. Power cycle the node and try to power it on: (2.1) Power off the node and pull out all Power Supply cables on the node from rear end
3. If the above steps fail to bring up the node and also no output via ILOM serial console, System Board will need replacement. Replace faulty System Board. At this stage we should have access to ILOM, even if the Node does not boot up. We will have to look into the ILOM snapshot for more information.
4. If ILOM is 2.x , please run these IPMI tool commands from a Linux machine within customer network and capture the output: ipmitool -H <ipaddress of SP or CMM> -U root fru
ipmitool -H <ipaddress of SP or CMM> -U root sel elist ipmitool -H <ipaddress of SP or CMM> -U root -v sdr ipmitool -H <ipaddress of SP or CMM> -U root sdr elist ipmitool -H <ipaddress of SP or CMM> -U root sdr list ipmitool -H <ipaddress of SP or CMM> -U root chassis status ipmitool -H <ipaddress of SP or CMM> -U root sunoem led get ipmitool -H <ipaddress of SP or CMM> -U root sensor ipmitool -H <ipaddress of SP or CMM> -U root mc info
5. Run these CLI commands via SSH or Serial Connection to ILOM and capture the output: show -l all
show -o table -level all show /SP/logs/event/list show faulty
6. If you are still unable to identify the failures from ILOM snapshot, IPMI tool commands or other CLI commands, then we need to bring the server to minimal config: Note: ILOM running on 2.x may not show correct IPMI sensor data. In this case , Upgrade the ILOM to latest for the testing and then bring the server to minimal config
(6.1) Remove all PCIE cards and risers - PSU1 (6.9) Once the server is fully configured, power on the server and check
7. At step 6.7 If you are still seeing the same issue, i.e no reading for ILOM sensors and no components reported for CPU and BIOS, Then replace the System Board again and start from step 6.6
8. If Node is powered on and you are unable to access it, make sure BIOS is set to appropriate values after System Board replacement.
9. Perform health check.
References<NOTE:1635390.1> - Sun Storage 7000 Unified Storage System: 7310 Array Will Not Boot<NOTE:2107944.1> - Sun Storage 7000 Unified Storage System: 7410 - Required BIOS Settings Attachments This solution has no attachment |
||||||||||||||||||||
|