Solution Type  Problem Resolution Sure

Solution  2389993.1 :   Oracle SuperCluster: Extract of .war archive, using /usr/bin/jar, on NFS share taking longer than usual  


Related Items
  • Oracle SuperCluster M7 Hardware
  •  
  • Oracle ZFS Storage ZS3-4
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: ZS-ES
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-17298441966>

Applies to:

Oracle SuperCluster M7 Hardware - Version All Versions and later
Oracle ZFS Storage ZS3-4 - Version All Versions and later
7000 Appliance OS (Fishworks)

Symptoms

Extracting a ~200MB archive on a SuperCluster compute node (using /usr/bin/jar) used to take <10sec - after upgrading to Jan 2018 QDSFP for SuperCluster, the extract takes >20min.

 

Changes

Jan 2018 QDSFP was applied to SuperCluster.

 

Cause

Changes in Jan 2018 QDSFP upgraded /usr/bin/jar

 

Solution

Issue is not related to the ZFS Storage Appliance.

Extract testing of .war archive, using /usr/bin/tar locally on appliance and from client was within 10 seconds. This appears to be an issue using jar.

 

Workaround is to use '/usr/bin/tar xvzf archive.war' to extract the .war archive instead.

 