![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2389371.1 : Oracle ZFS Network Aggregates and VNICs show Link status as UP when Physical Ports are DOWN
In this Document
Created from <SR 3-11150457011> Applies to:Oracle ZFS Storage ZS5-4 - Version All Versions to All Versions [Release All Releases]Oracle ZFS Storage ZS5-2 - Version All Versions to All Versions [Release All Releases] Oracle ZFS Storage ZS4-4 - Version All Versions to All Versions [Release All Releases] Oracle ZFS Storage ZS3-4 - Version All Versions to All Versions [Release All Releases] Oracle ZFS Storage ZS3-2 - Version All Versions to All Versions [Release All Releases] 7000 Appliance OS (Fishworks) SymptomsNewly configured Aggregation Datalinks and VNICs showing in the UP state. No network cables setup up yet on physical ports. CauseInitial configuration of the Networking components. SolutionThis is not a problem. According to information from this bug: 21646085 - Aggregate datalink shows as UP when all devices under it are DOWN "That the link state of the aggr and the vnics must be UP even though the underlying ports may not even be cabled is by design. This is because the VNICs must be able to communicate with each other through the internal virtual switches even if there are no physical connections and hence no connection to the outside world. This link state being UP is also valid when there is only one VNIC, but the aggr is plumbed with an IP, because they should also be able to talk to each other. So in Cu's case this is not a bug, but a valid state." References<BUG:21646085> - AGGREGATE DATALINK SHOWS AS UP WHEN ALL DEVICES UNDER IT ARE DOWNAttachments This solution has no attachment |
||||||||||||||||||
|