Solution Type Problem Resolution Sure Solution 2386645.1 : Eagle: Need To Disable Gateway Measurement Reports Getting Pushed To FTP Server
In this Document
Created from <SR 3-17274488991> Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 46.0 and laterTekelec SymptomsGetting lots of gateway related measurement files in E5-MS path /var/E5-MS/measurement/csvoutput/others which are not in use and taking too much space on the server.
Changes
CauseGateway measurements are turned ON in STP > rtrv-measopts
tekelecstp 18-04-12 17:34:45 IST EAGLE 46.5.0.0.1-70.39.1 rtrv-measopts Command entered at terminal #22. ; Command Accepted - Processing tekelecstp 18-04-12 17:34:45 IST EAGLE 46.5.0.0.1-70.39.1 PLATFORMENABLE = off COLLECT15MIN = on CLLIBASEDNAME = on OAMHCMEAS = on UNCHLINKLABEL = on ---------------------- SYSTOTSTP = on SYSTOTTT = on SYSTOTSTPLAN = on SYSTOTIDPR = on SYSTOTSIP = on SYSTOTSFTHROT = on COMPLINK = on COMPLNKSET = on COMPSCTPASOC = on COMPSCTPCARD = on COMPUA = on GTWYSTP = on GTWYLNKSET = on GTWYORIGNI = on GTWYORIGNINC = on GTWYLSORIGNI = on GTWYLSDESTNI = on GTWYLSONISMT = on NMSTP = on NMLINK = on NMLNKSET = on AVLLINK = on AVLSTPLAN = on AVLDLINK = on ; Command Executed SolutionIf gateway measurement reports are not required to be transferred to FTP server then the below measurements can be turned OFF in the STP GTWYLNKSET = on
GTWYORIGNI = on GTWYORIGNINC = on GTWYLSORIGNI = on GTWYLSDESTNI = on GTWYLSONISMT = on The below command can used to turn off the above gateway measurements, chg-measopts:off=GTWYLNKSET,GTWYORIGNI,GTWYORIGNINC,GTWYLSORIGNI,GTWYLSDESTNI,GTWYLSONISMT