Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2386645.1
Update Date:2018-04-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  2386645.1 :   Eagle: Need To Disable Gateway Measurement Reports Getting Pushed To FTP Server  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec EMS
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-17274488991>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 46.0 and later
Tekelec

Symptoms

Getting lots of gateway related measurement files in E5-MS path /var/E5-MS/measurement/csvoutput/others which are not in use and taking too much space on the server.


Need To Disable Gateway Measurement Reports Getting Pushed To FTP Server

Changes

 

Cause

Gateway measurements are turned ON in STP

> rtrv-measopts

  tekelecstp 18-04-12 17:34:45 IST EAGLE 46.5.0.0.1-70.39.1
  rtrv-measopts
  Command entered at terminal #22.
;

Command Accepted - Processing
  tekelecstp 18-04-12 17:34:45 IST EAGLE 46.5.0.0.1-70.39.1
  PLATFORMENABLE = off
  COLLECT15MIN = on
  CLLIBASEDNAME = on
  OAMHCMEAS = on
  UNCHLINKLABEL = on
  ----------------------
  SYSTOTSTP = on
  SYSTOTTT = on
  SYSTOTSTPLAN = on
  SYSTOTIDPR = on
  SYSTOTSIP = on
  SYSTOTSFTHROT = on
  COMPLINK = on
  COMPLNKSET = on
  COMPSCTPASOC = on
  COMPSCTPCARD = on
  COMPUA = on
  GTWYSTP = on
  GTWYLNKSET = on
  GTWYORIGNI = on
  GTWYORIGNINC = on
  GTWYLSORIGNI = on
  GTWYLSDESTNI = on
  GTWYLSONISMT = on
  NMSTP = on
  NMLINK = on
  NMLNKSET = on
  AVLLINK = on
  AVLSTPLAN = on
  AVLDLINK = on

;
Command Executed

 
Gateway measurements were enabled in the STP and hence the STP was sending the gateway reports to the configured FTP server.
 

Solution

If gateway measurement reports are not required to be transferred to FTP server then the below measurements can be turned OFF in the STP

 GTWYLNKSET = on
 GTWYORIGNI = on
 GTWYORIGNINC = on
 GTWYLSORIGNI = on
 GTWYLSDESTNI = on
 GTWYLSONISMT = on

 The below command can used to turn off the above gateway measurements,

chg-measopts:off=GTWYLNKSET,GTWYORIGNI,GTWYORIGNINC,GTWYLSORIGNI,GTWYLSDESTNI,GTWYLSONISMT

 