Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2386560.1
Update Date:2018-04-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  2386560.1 :   Eagle: UIM 1223 - SCCP Did Not Route - Bad Translation  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-17282440901>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 46.0 and later
Tekelec

Symptoms

Customer complained that messages coming from the MSC having as destination a third party platform we're not routed by the STP and that UIM 1223 was received - "SCCP did not route - bad translation".

7863.1223    CARD 1305     INFO    SCCP did not route - bad translation

                 SIO=83   OPC=   xxxxx          DPC=   yyyyy        

                 SCCP MSG TYPE=09

                 CDPA:  NI=0  RI=0  GTI=04  SSNI=1  PCI=0

                        TT=000  NP=01  NAI=003  ADDR=111111111

                        PC=--------------    SSN=006

                 CGPA:  NI=0  RI=0  GTI=04  SSNI=1  PCI=0

                        TT=000  NP=01  NAI=004  ADDR=222222222222

                        PC=--------------    SSN=008

                 LSN=lsnname  GTTSETIDX=0                                          

                 Report Date:18-04-13  Time:10:48:57

 

 

Changes

 

Cause

The STP received the message with the GT in a national format, which was not defined in the e164natl set table in the STP causing the translation to fail.

  tekelecstp 18-04-13 13:25:21 HST EAGLE 46.5.0.0.1-70.39.1

  rtrv-gta:gttsn=e164natl:gta=111111111

  Command entered at terminal #20.

;

 

E2405 Cmd Rej: GTA/SADDR does not exist in any range

Trace info:

    tekelecstp 18-04-13 13:34:50 HST  EAGLE 46.5.0.0.1-70.39.1

    MSU TRACE H'0038:  Card=1305

    Trace ID 8 Condition: (brief=Y, MSU size=173)

    LOC=          1305

    GT=           111111111

    SI=           3

    MODE=         debug

    

    Info: GTT FAILED: TRANS_ENTRY_NOT_FOUND-2

 

Solution

The solution was to define the 6391999xx range for GT translation in the e164natl table. After the definition, calls were OK and no more UIMs 1223 were received.

ent-gta:gttsn=e164natl:gta=111111111:egta=111111119:xlat=dpc:ri=ssn:pcn=xxxxx


 

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback