![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2386560.1 : Eagle: UIM 1223 - SCCP Did Not Route - Bad Translation
In this Document
Created from <SR 3-17282440901> Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 46.0 and laterTekelec SymptomsCustomer complained that messages coming from the MSC having as destination a third party platform we're not routed by the STP and that UIM 1223 was received - "SCCP did not route - bad translation". 7863.1223 CARD 1305 INFO SCCP did not route - bad translation SIO=83 OPC= xxxxx DPC= yyyyy SCCP MSG TYPE=09 CDPA: NI=0 RI=0 GTI=04 SSNI=1 PCI=0 TT=000 NP=01 NAI=003 ADDR=111111111 PC=-------------- SSN=006 CGPA: NI=0 RI=0 GTI=04 SSNI=1 PCI=0 TT=000 NP=01 NAI=004 ADDR=222222222222 PC=-------------- SSN=008 LSN=lsnname GTTSETIDX=0 Report Date:18-04-13 Time:10:48:57
Changes
CauseThe STP received the message with the GT in a national format, which was not defined in the e164natl set table in the STP causing the translation to fail. tekelecstp 18-04-13 13:25:21 HST EAGLE 46.5.0.0.1-70.39.1 rtrv-gta:gttsn=e164natl:gta=111111111 Command entered at terminal #20. ;
E2405 Cmd Rej: GTA/SADDR does not exist in any range Trace info: tekelecstp 18-04-13 13:34:50 HST EAGLE 46.5.0.0.1-70.39.1 MSU TRACE H'0038: Card=1305 Trace ID 8 Condition: (brief=Y, MSU size=173) LOC= 1305 GT= 111111111 SI= 3 MODE= debug
Info: GTT FAILED: TRANS_ENTRY_NOT_FOUND-2
SolutionThe solution was to define the 6391999xx range for GT translation in the e164natl table. After the definition, calls were OK and no more UIMs 1223 were received. ent-gta:gttsn=e164natl:gta=111111111:egta=111111119:xlat=dpc:ri=ssn:pcn=xxxxx