Solution Type  Problem Resolution Sure

Solution  2386137.1 :   LSMS Are Not Allowing Sftp To Iconectiv  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS ELAP LSMS
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-17277672811>

Applies to:

Oracle Communications EAGLE (Hardware) - Version LSMS 13.3 and later
Information in this document applies to any platform.

Symptoms

Unable to sftp to iconnectiv servers from local LSMS servers.

Changes

 

Cause

There is a conflict between IP addresses within the known_hosts files that need to be resolved
 
Access to servers required in order for database changes to be received.
 

Solution

Here are the steps to resolve the issue:
1.While using the the command line interface run the following command: cat known_hosts.
2. locate the conflicting IP address and remove them by editing the known_hosts file using linux/unix commands.
3. Save the changes and then retry the sftp function.

 