Asset ID: |
1-72-2386022.1 |
Update Date: | 2018-04-16 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2386022.1
:
SL3000 - Cannot Change CAP Ownership in Partition, Error: "Locked by Another Requester"
Related Items |
- Sun StorageTek SL3000 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Created from <SR 3-17264072201>
Applies to:
Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Library has 2 partitions. Customer wants to switch from partition 2 to partition 1.
Symptoms
Cannot Change CAP Ownership in Partition, Error: "Locked by Another Requester".
The CAP is empty, closed and reboots do not help.
Changes
Cause
CAP needed to be reconfigured.
Solution
Allocating Resources to a Partition
Select the Tools > Partitions > Module Map (Step 3a) tab.
Select a module, and then click the Design (Step 3b) tab.
Select a partition ID from the drop-down list.
In the Select by drop-down list, select a range. Then, select Add or Remove.
Use the library map to select the resources to add or remove. Partitions can be non-contiguous.
Note:
To re-assign a resource from one partition to another, remove the resource from the initial partition before re-allocating it.
Repeat for each partition ID. When the partition design is complete, click Verify.
Caution:
If there are warnings, click Details and perform recovery moves on the orphaned cartridges. (see "Moving Cartridges (Recovery Moves"). Once done, re-verify the design.
If there are no warnings, proceed to see "Committing Partitioning Changes".
Attachments