Asset ID: |
1-72-2385547.1 |
Update Date: | 2018-05-24 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2385547.1
:
Unexpected SAM Received
Related Items |
- Oracle Communications EAGLE (Hardware)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 3-15813261641>
Applies to:
Oracle Communications EAGLE (Hardware) - Version EAGLE 46.3 and later
Information in this document applies to any platform.
Symptoms
After rebooting the Eagle, all IPGWI cards are receiving unexpected SAM messages
Changes
0583 - Unexpected SAM Received
This indicates that an FC enabled card received an erroneous SAM from IMF.
Unexpected SAM Received if a Mismatched Fast Copy Network Addresses
Cause
It happened further to the action "FailOver" when moving the monitored links to another IMF Server.
Solution
Initing the card or using the pass command scopy solves the issue. or waiting for several days it clears on its own.
pass:loc=IPGHC:cmd="scopy 4000 -z"
References
<NOTE:2197296.1> - Message Timestamping Issue On EAGLE Running R46.3 May Affect Data Correlation On PIC
Attachments
This solution has no attachment