![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2385542.1 : Increasing The Counter "recv Timer Count"
In this Document
Created from <SR 3-16185947201> Applies to:Oracle Communications EAGLE (Hardware) - Version EAGLE 46.3 to EAGLE 46.6 [Release EAGLE 46.0]Information in this document applies to any platform. SymptomsIncreasing the counter "recv timer count" on Eagle Associations: ChangesUser had a query to understand the case of increasing the "recv timer count" on Eagle Associations: CauseUser found the "recv timer count" increasing on Eagle Associations: and wanted to understand the situation in which the recv. timer would be increased on Eagle association. Solutionrecv timer can also be communicated as the SACK timer “recv timer count” is the sum of the receive timer (i.e. SACK timer, delayed acknowledgement timer etc..) expires on the association,