Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2384643.1
Update Date:2018-04-10
Keywords:

Solution Type  Problem Resolution Sure

Solution  2384643.1 :   Failed USB Memory Stick Caused ILOM Interconnect Failure  


Related Items
  • SPARC S7-2L
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: S7
  •  




Created from <SR 3-16935956550>

Applies to:

SPARC S7-2L - Version All Versions and later
Information in this document applies to any platform.

Symptoms

The following faults are seen:

Mar 21 06:30:40 1dc38a0a-f361-41fe-8963-eb2e48fcc7d6 FMD-8000-D6 Diagnosed
Mar 21 08:06:06 600064db-a82f-4545-8f23-dbfed345d280 USB-8000-2W Diagnosed

ilomconfig indicates that there is no host interconnect address:

# ilomconfig list interconnect
Interconnect
============
State: enabled
Type: USB Ethernet
SP Interconnect IP Address: 169.254.182.76
Host Interconnect IP Address: (none)       <----
Interconnect Netmask: 255.255.255.0
SP Interconnect MAC Address: 02:21:xx:xx:xx:xx
Host Interconnect MAC Address: 02:21:xx:xx:xx:xx

 

ilomconfig -a shows that the ILOM interconnect's address is proper:

sysconfig/ifconfig-a.out
  net8: flags=100001000843"UP,BROADCAST,RUNNING,MULTICAST,IPv4,PHYSRUNNING" mtu 1500 index 3
  inet 169.254.182.77 netmask ffffff00 broadcast 169.254.182.255 ether 0:0:0:0:0:2

 

dladm show-phys -Z indicates that this net is not associated with usbecm2:

netinfo/dladm/dladm_show-phys_-Z.out
  net8 global Ethernet up 0 unknown clprivnet0

 

The messages file contains the following message near the time of the faults:
  Mar 21 06:14:33 ca1 scsi: [ID 107833 kern.warning] WARNING: /pci@300/pci@1/pci@0/pci@2/usb@0/hub@2/storage@3/disk@0,0 (sd1):
  Mar 21 06:14:33 ca1 SCSI transport failed: reason 'tran_err': retrying command

Cause

A failed USB memory stick was inserted into an external USB port (/pci@300/pci@1/pci@0/pci@2/usb@0/hub@2/storage@3/disk@0,0).

Solution

The USB stick was removed.

References

<NOTE:2281470.1> - How to troubleshoot the FMA ip-transport module alerts
<NOTE:2266235.1> - "ldm list-config" Fails with an ILOM Interconnect Message
<NOTE:2216293.1> - Commands To Clear FMA faults on the T5-x, T7-x, S7-x Servers