![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2384378.1 : Eagle: Eagle May Send SACK With Incorrect Chunk Length When Shutdown Chunk Is Appended To It
In this Document
Created from <SR 3-10105124281> Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 45.0 to EAGLE 46.3 [Release EAGLE 45.0 to EAGLE 46.0]Tekelec Symptoms
SACK chunk (Cumulative TSN: 2025663772, a_rwnd: 204800, gaps: 0, duplicate TSNs: 0) Chunk type: SACK (3) ------------------------------------------->1 byte Chunk flags: 0x00 ---------------------------------------------->1 byte Chunk length: 24 ----------------------------------------------->2 bytes Cumulative TSN ACK: 2025663772 --------------------------------->4 bytes Advertised receiver window credit (a_rwnd): 204800 ------------->4 bytes Number of gap acknowledgement blocks: 0 ------------------------>2 bytes Number of duplicated TSNs: 0 ----------------------------------->2 bytes
Changes
Cause
SolutionUpgrade to Eagle 46.3 or higher release which has the fix to Bug 20802492
References<BUG:20802492> - SR: SACK WITH INCORRECT CHUNK LENGTH WHEN A SHUTDOWN CHUNK IS APPENDED TO ITAttachments This solution has no attachment |
||||||||||||||||||||
|