Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2383709.1
Update Date:2018-04-10
Keywords:

Solution Type  Problem Resolution Sure

Solution  2383709.1 :   T10000 A/B - FSC 48DF  


Related Items
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: fix fsc 48df
Created from <SR 3-17223404147>

Applies to:

Sun StorageTek T10000B Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 Drive dump reporting FSC: 48DF RO_FSC_READ_NEXT_WRAP_INCORRECT_START_FLAG

Changes

 N/A

Cause

The MIR data inconsistent.

FSC Dictionary Description:
MODEL = T10000B
FSC = 48DF
(FSC Match Found in Rev. 1.52)

FSC: 48DF RO_FSC_READ_NEXT_WRAP_INCORRECT_START_FLAG
MIM Code: INOPERABLE
FRU: MICROCODE CONF: 100%
Summary: |INVALID UCODE |GLOBAL VALUE | *** |
Field Text:
The MIR data inconsistent.

Engineering Text:
The MIR was asked for location information for the start of the next wrap. This location information was cross checked and found to not indicate start of wrap. The read code was stopped since it could not reliably go to the next wrap of tape.

Support Annotations:
   
T10000A/B - 48DF FSC - See bug 24558693. Note: This change will only be available via special build. It will not go into released code.

Solution

Upgrade drive to RA.52.x06 Special Build code to address FSC 48DF.

Engage L2 to apply and download this code from https://tapesupport.us.oracle.com/Procedures/SpecialBuilds/code-downloadv2/code-download.php

References

<NOTE:2383708.1> - T10000 A/B - FSC 48DF

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback