IBM LTO4 - ND - SLO2 - We See The Backup Writes On Drive , 7035: FsczzERRMAP_MED_OVER_REWRITE_LIMIT
Related Items |
- Sun StorageTek SL8500 Modular Library System
- IBM LTO4 Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-17231112852>
Applies to:
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
IBM LTO4 Tape Drive - Version All Versions and later
Information in this document applies to any platform.
Symptoms
ProblemDescription>We see the backup writes on drive "L4_4_6_1_5_SL85_02" are failing and error log</ProblemDescription>
<ProblemNotes>We see the backup writes on drive "L4_4_6_1_5_SL85_02" are failing and error log we see as below ....00:20:35.201 47215 2 parse_resource_strings: DRIVE 4 L4_4_6_1_5_SL85_02 2000463 1310282310 /dev/nst3 -1 -1 -1 -1 4 6 1 5 *NULL* *NULL* *NULL* *NULL* 1 0 0 1 0 0 *NULL*..00:20:36.304 47215 2 drivename_open: Called with Create 1, file L4_4_6_1_5_SL85_02..00:20:37.324 47215 4 exp INC08L7V
0 7035: Number of Dataset CQ > 192 FUJIFILM 45T62GE9 C7QH (df120723q) 7035: Number of Dataset CQ > 192 04h 50 01 43 80 21 e1 83 72 6 32 6: Drive or Media 922231879 0d 08h:08m:30s BR3902L4 32
1 7035: Number of Dataset CQ > 192 FUJIFILM 45T62GE9 C7QH (df120723q) 7035: Number of Dataset CQ > 192 04h 50 01 43 80 21 e1 83 72 10 32 6: Drive or Media 275375638 0d 15h:04m:02s BR3902L4 32
2 7035: Number of Dataset CQ > 192 FUJIFILM 45T62GE9 C7QH (df120723q) 7035: Number of Dataset CQ > 192 04h 50 01 43 80 21 e1 83 72 10 32 6: Drive or Media 865571032 0d 15h:08m:00s BR3902L4 32
3 7035: Number of Dataset CQ > 192 FUJIFILM 45T62GE9 C7QH (df120723q) 7035: Number of Dataset CQ > 192 04h 50 01 43 80 21 e1 83 72 10 32 6: Drive or Media 648062425 0d 15h:11m:04s BR3902L4 32
4 7067: Medium Excessive Wrt Recovery FUJIFILM 45T5Y5UW C7QH (df120723q) 7067: Medium Excessive Wrt Recovery 03h 50 01 43 80 21 e1 04 02 39 32 6: Drive or Media 268984364 0d 16h:07m:06s BR4328L4 30
5 7067: Medium Excessive Wrt Recovery FUJIFILM 45T5Y5UW C7QH (df120723q) 7067: Medium Excessive Wrt Recovery 03h 50 01 43 80 21 e1 04 02 39 32 6: Drive or Media 605193213 0d 16h:09m:08s BR4328L4 30
6 7067: Medium Excessive Wrt Recovery FUJIFILM 45T5Y5UW C7QH (df120723q) 7067: Medium Excessive Wrt Recovery 03h 50 01 43 80 21 e1 04 02 39 32 6: Drive or Media 717889092 0d 16h:12m:12s BR4328L4 30
7 7035: Number of Dataset CQ > 192 FUJIFILM 45T62L72 C7QH (df120723q) 7035: Number of Dataset CQ > 192 02h 50 01 43 80 21 e1 6a f6 111 32 6: Drive or Media 285827880 0d 16h:30m:03s BR4329L4 44
8 7035: Number of Dataset CQ > 192 FUJIFILM 45T62L72 C7QH (df120723q) 7035: Number of Dataset CQ > 192 02h 50 01 43 80 21 e1 6a f6 111 32 6: Drive or Media 766472122 0d 16h:37m:48s BR4329L4 44
9 7035: Number of Dataset CQ > 192 FUJIFILM 45T62L72 C7QH (df120723q) 7035: Number of Dataset CQ > 192 02h 50 01 43 80 21 e1 6a f6 111 32 6: Drive or Media 965140486 0d 16h:40m:52s BR4329L4 44
7035: FsczzERRMAP_MED_OVER_REWRITE_LIMIT
The number of CQ of a dataset is larger than 192.
Bad media condition, Drive is not calibrated, Bad data channel condition or head damaged.
Changes
Cause
7035: FsczzERRMAP_MED_OVER_REWRITE_LIMIT
The number of CQ of a dataset is larger than 192.
Bad media condition, Drive is not calibrated, Bad data channel condition or head damaged.
Solution
Drive needs to be replaced.
Attachments
This solution has no attachment