![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2382765.1 : T10000C - The MIR Data Is Inconsistent With Code State, FSC3 923
In this Document
Created from <SR 3-17119357680> Applies to:StorageTek T10000C Tape Drive - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsFSC(3923): CST_UNLOAD event. The MIR data is inconsistent with code state. CauseMIM Code: INOPERABLE SolutionOpen a collaboration to L2 Tape Support to verify firmware is needed. Need to install the Special build code RA365103 on the drive to fix the 3923 FSC. Attachments This solution has no attachment |
||||||||||||||||
|