Solution  2382765.1 :   T10000C - The MIR Data Is Inconsistent With Code State, FSC3 923  


Related Items
  • StorageTek T10000C Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-17119357680>

Applies to:

StorageTek T10000C Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

FSC(3923): CST_UNLOAD event. The MIR data is inconsistent with code state.

Cause

MIM Code: INOPERABLE

FRU: MICROCODE CONF: 100%

Summary: |INVALID UCODE |RETURN CODE | *** |
 
MIR data is inconsistent with code state.
 

Solution

Open a collaboration to L2 Tape Support to verify firmware is needed.

Need to install the Special build code RA365103 on the drive to fix the 3923 FSC.
 