Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2381811.1
Update Date:2018-04-03
Keywords:

Solution Type  Problem Resolution Sure

Solution  2381811.1 :   Eagle: RTRV-GTA Command Retrieves GTA Entries Incorrectly When EGTA Parameter Is Specified  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-16966715641>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 46.3 and later
Tekelec

Symptoms

The output for rtrv-gta  command is inconsistent when EGTA parameter is specified, as non-matching values are also displayed.

tekelecstp 18-02-28 10:16:04 EST EAGLE 46.3.1.0.0-68.30.1
rtrv-gta:gttsn=e164intl:gta=1100:egta=1199:force=yes:num=1000
Command entered at terminal #28.
;

Command Accepted - Processing
tekelecstp 18-02-28 10:16:04 EST EAGLE 46.3.1.0.0-68.30.1

GTTSN NETDOM SETTYPE REFCNT NPSN NDGT
e164intl itu CDGTA 15 ----- 2,3,4,5,6,7,8,9,10,11

GTA table is (7909 of 269999) 3% full.

;
tekelecstp 18-02-28 10:16:04 EST EAGLE 46.3.1.0.0-68.30.1

START GTA END GTA XLAT RI ITU PC
1170 1170 dpc gt xxxxxx
MRNSET=45 SSN=--- CCGT=no
GTMODID=--------- TESTMODE=off
FALLBACK=sysdflt
OPTSN=--------- CGSELID=----- CDSELID=----- OPCSN=---------
ACTSN=--------- PPMEASREQD= no
CGPCACTION=dflt
1211 1211 dpc gt xxxxxxx
MRNSET=4 SSN=--- CCGT=no
GTMODID=--------- TESTMODE=off
FALLBACK=sysdflt
OPTSN=--------- CGSELID=----- CDSELID=----- OPCSN=---------
ACTSN=--------- PPMEASREQD= no
CGPCACTION=dflt

 

Cause

This is a known bug in R46.3.

Bug# 25379462 - RTRV-GTA command retrieves GTA entries incorrectly when EGTA is specified.
 

Solution

It is advised to upgrade to R46.5 or later release which has the fix to Bug# 25379462.

As a workaround, use only GTA parameter in rtrv-gta command (avoid usage of EGTA parameter).

References

<BUG:25379462> - SR: RTRV-GTA COMMAND RETRIEVES GTA ENTRIES INCORRECTLY WHEN EGTA IS SPECIFIED

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.