![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2381811.1 : Eagle: RTRV-GTA Command Retrieves GTA Entries Incorrectly When EGTA Parameter Is Specified
In this Document
Created from <SR 3-16966715641> Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 46.3 and laterTekelec SymptomsThe output for rtrv-gta command is inconsistent when EGTA parameter is specified, as non-matching values are also displayed. tekelecstp 18-02-28 10:16:04 EST EAGLE 46.3.1.0.0-68.30.1 Command Accepted - Processing GTTSN NETDOM SETTYPE REFCNT NPSN NDGT GTA table is (7909 of 269999) 3% full. ; START GTA END GTA XLAT RI ITU PC
CauseThis is a known bug in R46.3. Bug# 25379462 - RTRV-GTA command retrieves GTA entries incorrectly when EGTA is specified. SolutionIt is advised to upgrade to R46.5 or later release which has the fix to Bug# 25379462. As a workaround, use only GTA parameter in rtrv-gta command (avoid usage of EGTA parameter). References<BUG:25379462> - SR: RTRV-GTA COMMAND RETRIEVES GTA ENTRIES INCORRECTLY WHEN EGTA IS SPECIFIEDAttachments This solution has no attachment |
||||||||||||||||||
|