Solution Type Problem Resolution Sure Solution 2381577.1 : Oracle ZFS Storage Appliance: Power supplies show faulty in BUI, but show OK in ILOM
AK shows a power supply as faulted after a external power event, even though power has been restored and ILOM shows power supplies to be ok. In this Document
Created from <SR 3-17034266604> Applies to:Oracle ZFS Storage ZS4-4 - Version All Versions and laterOracle ZFS Storage ZS5-4 - Version All Versions and later Oracle ZFS Storage ZS5-2 - Version All Versions and later Oracle ZFS Storage ZS3-4 - Version All Versions and later Oracle ZFS Storage ZS3-2 - Version All Versions and later 7000 Appliance OS (Fishworks) SymptomsAfter a power event caused temporary loss of power to one PDU in the rack, PS0 on both heads of the array continued to show faulty in the BUI after power was restored.
ChangesNone. CausePower supplies show faulty, but are actually OK.
SolutionThe lights on the power supplies were ON, the ILOM showed the power supplies as OK.
From the CLI, the command 'raw hardware.refresh()' was issued, which caused AKD to re-read the hardware status which resolved the issue. Attachments This solution has no attachment |
||||||||||||||||||
|