Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2381577.1
Update Date:2018-05-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  2381577.1 :   Oracle ZFS Storage Appliance: Power supplies show faulty in BUI, but show OK in ILOM  


Related Items
  • Sun ZFS Storage 7420
  •  
  • Oracle ZFS Storage ZS5-2
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Oracle ZFS Storage ZS5-4
  •  
  • Sun ZFS Storage 7120
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage ZS3-BA
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: ZS
  •  


AK shows a power supply as faulted after a external power event, even though power has been restored and ILOM shows power supplies to be ok.

In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-17034266604>

Applies to:

Oracle ZFS Storage ZS4-4 - Version All Versions and later
Oracle ZFS Storage ZS5-4 - Version All Versions and later
Oracle ZFS Storage ZS5-2 - Version All Versions and later
Oracle ZFS Storage ZS3-4 - Version All Versions and later
Oracle ZFS Storage ZS3-2 - Version All Versions and later
7000 Appliance OS (Fishworks)

Symptoms

After a power event caused temporary loss of power to one PDU in the rack, PS0 on both heads of the array continued to show faulty in the BUI after power was restored.

 

Changes

None.

Cause

Power supplies show faulty, but are actually OK.

 

Solution

The lights on the power supplies were ON, the ILOM showed the power supplies as OK.

 

From the CLI, the command 'raw hardware.refresh()' was issued, which caused AKD to re-read the hardware status which resolved the issue.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.