Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2380334.1
Update Date:2018-04-05
Keywords:

Solution Type  Problem Resolution Sure

Solution  2380334.1 :   T10000C - FSC: 376D RO_FSC_READ_TIMEOUT_NO_AT_SPEED_DETECTED  


Related Items
  • StorageTek T10000C Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: Remote
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-17130330224>

Applies to:

StorageTek T10000C Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Host Name: not_applicable
Product Type: T10000C
Summary:Trap 24/SNO occurred but no FSC sent. Collect drive dump to determine cause of SNO.

Internal Software Error. Should Not Occur.
************* ADDITIONAL INFORMATION *************
*** Alarm Description ***
 FSC(NOSNO): Internal Software Error. Should Not Occur.
Internal Software Error. Should Not Occur.
Device Dmod: 576004001697
Tray SN: 576000203697
Device Model: T10000C
Trap Type: tapenewdumpdetected
Locator Text: ACS/LSM/Pnl/Drv: 0/0/0/0, Library: SL8500 : SL8500_1, Drive Location: 1,2,1,1,3, Mfg S/N: 576004001697, Tray S/N: 57600020369

Changes

 

Cause

The drive had encountered FSC: 376D Drive: with Volser: 806567T2

FSC Dictionary Description:
MODEL = T10000C
FSC = 376D
(FSC Match Found in Rev. 3.65)

FSC: 376D RO_FSC_READ_TIMEOUT_NO_AT_SPEED_DETECTED
MIM Code: TOLERANCE
FRU: MEDIA CONF: 50%
FRU: HARDWARE CONF: 50%
Summary: |SERVO RAMP UP |ERROR | *** |
Field Text:
The read code timed out waiting for an interrupt to occur. The servo never indicated that it had acquired the correct track.

Engineering Text:
The read code timed out waiting for an interrupt to occur. AT SPEED was never received from the servo.

Support Annotations:
   
T10000A/B/C/D - FSC 376D - These failures can be caused by a bad tape but they can also be caused by a marginal drive. Monitor both the tape and the drive. Action steps can only come once the failure repeats either following the tape or the drive. T10KC Drive code 3.65.103 (or greater) has a code change for the stepper motor that should help with these errors.

Bug 26787276 : FSC: 376D RO_FSC_READ_TIMEOUT_NO_AT_SPEED_DETECTED.
Confirms that this is servo error and is fixed in 3.65.103 microcode release.

 

Solution

Issue resolved with release of 3.65.103 drive code.  Firmware should be updated.

References

<BUG:26787276> - FSC: 376D RO_FSC_READ_TIMEOUT_NO_AT_SPEED_DETECTED
<NOTE:2269372.1> - T10000 - How To Force A Tape Drive Dump From The Library
<NOTE:1509702.1> - SL3000/SL8500 - Take the Time to Obtain a SnapShot !

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback