![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2379776.1 : SL8500 - Safety Door Hits Handbots on the Left Side
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL8500 Modular Library System - Version All Versions and laterInformation in this document applies to any platform. SSD = Service Safety Door Have done a lot of IPLs and sometimes the safety door is doing initial move to left and right even when Bots are not safe outside. Have closed the Safety Door to the left and a robot came to check the CAP and hit the "closed" Safety door. Its like the HBCR does not know the Safety door status. (all switches and cables are measured and ok). SymptomsSafety Door hits Handbots on the Left Side. Move to the right never causes collisions or other problems. CauseThe door guide plate on the floor is on backwards. SolutionThe "StorageTek SL8500 Installation Manual for Bulk CAP Libraries" shows how to install the service safety door on page 172 but it does not mention installing the guide plate anywhere in the manual. Attachments This solution has no attachment |
||||||||||||||||
|