Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2375663.1
Update Date:2018-03-20
Keywords:

Solution Type  Problem Resolution Sure

Solution  2375663.1 :   Default Route Stopped Working after an SP reset  


Related Items
  • Oracle Switch ES1-24
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Ethernet Switches
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-16915820851>

Applies to:

Oracle Switch ES1-24 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Can not ping to an IP address on the other side of the default router  after a power cycle or SP reset.
A snoop or tcpdump on the end system showed the failed ICMP packet arriving with a source IP of 0.0.0.0, so the end system was not able to respond. 
 

Cause

 This is a defect (27668943)  and triggered when ipv6  address is assigned to the default vlan 1.
 

 

Solution

Permanent fix to be released in a future firmware update (1.3.1.23). A work around is to shut down the IP interface on vlan 1 from the sefos prompt.

config t
int vlan 1
shut
end
write start


 

References

<BUG:27668943> - DEFAULT ROUTE STOPPED WORKING AFTER AN SP RESET

Attachments
This solution has no attachment