Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2374294.1
Update Date:2018-03-19
Keywords:

Solution Type  Problem Resolution Sure

Solution  2374294.1 :   SL8500/HSC - Cannot Get CAP 00:01:00 To Come Off-line Or Free Up  


Related Items
  • Sun StorageTek Host Software Component (HSC)
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-17064433071>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]
Sun StorageTek Host Software Component (HSC) - Version 7.3 and later
Information in this document applies to any platform.

Symptoms

 Tape is stuck in the robot and we cannot get CAP 00:01:00 to come off-line or free up. The status of CAP 01:00:00 says ejecting, but no tapes have been ejected from the CAP.

Changes

 

Cause

 CAPs were not functioning.

Solution

Procedure that was used to clear this issue:

1. Issue ".D CAP" from HSC and CAP shows "RECOVERY" status (waited as long as an hour to self clear).
2. "UNLOCKED" light never illuminates on Op Panel - ".ENTER" command hangs if attempted.
3. Issue HSC command ".CAPPREF 9 00:01:00 MANUAL".
4. HSC responds with "CAP 00:01:00 Already in Manual Mode".
5. Issue HSC command ".CAPPREF 9 00:01:00 AUTO".
6. HSC responds with "Attempting Cleanup of CAP 00:01:00".
7. After a few minutes the "RECOVERY" status changes to "AUTO".
8. The "UNLOCKED" light illuminates on the OP Panel and the CAP is fully functional.
 

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.