Created from <SR 3-17047611641> Applies to:Oracle ZFS Storage ZS3-2 - Version All Versions and later7000 Appliance OS (Fishworks) SymptomsThe ZS3-2 was booted after a DIMM replacement and the following error messages was seen :- Can not boot to ILOM, use 'net flash' to reflash ILOM. The ZS3-2 then would boot. Seemly this would indicate the ILOM/SP is corrupted and would need re-flashing.
ChangesMaintenance for DIMM replacement was carried out before the boot.
CauseUpon inspection, it was found that the front panel display was disconnected.
SolutionRe-seated cable to front panel and problem was resolved - without replacing motherboard.