Solution  2373439.1 :   Oracle ZFS Storage Appliance: After ZS3-2 Reboot, Error Message Is Seen "Can not boot to ILOM, use 'net flash' to reflash ILOM"  


Related Items
  • Oracle ZFS Storage ZS3-2
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: ZS
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-17047611641>

Applies to:

Oracle ZFS Storage ZS3-2 - Version All Versions and later
7000 Appliance OS (Fishworks)

Symptoms

The ZS3-2 was booted after a DIMM replacement and the following error messages was seen :-

Can not boot to ILOM, use 'net flash' to reflash ILOM.

The ZS3-2 then would boot. Seemly this would indicate the ILOM/SP is corrupted and would need re-flashing.

 

Changes

Maintenance for DIMM replacement was carried out before the boot.

 

Cause

Upon inspection, it was found that the front panel display was disconnected.

 

Solution

Re-seated cable to front panel and problem was resolved - without replacing motherboard.