Asset ID: |
1-72-2373150.1 |
Update Date: | 2018-03-14 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2373150.1
:
SL3000 - Exceeded Threshold Set for a Healthy Robot (servo_mech_80percent) of Servo Mech Events
Related Items |
- Sun StorageTek SL3000 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-16961686611>
Applies to:
Sun StorageTek SL3000 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
Symptoms
Several tape drives at PEND-TLD status.
SLC is reporting a library component in a failed state.
Robot 1.1.0.2.0 is presenting errors exceeded threshold set for a healthy robot (servo_mech_80percent) of Servo Mech events.
Changes
Cause
Analysis of log snapshot detected errors exceeded threshold set for a healthy robot.
Solution
2018-02-26 21:49:35 |
 |
(SA-572) Analysis of log snapshot detected errors exceeded threshold set for a healthy robot. This robot must be replaced.
Refer to Knowledge document listed for replacement instructions.
Address/Loc: 1.1.0.2.0
Partnum: 7044401
Parttype: Robot
Library Type: SL3000
KnowledgeBase:
https://mosemp.us.oracle.com/epmos/faces/DocumentDisplay?id=1640738.1
Canned Action Plan:
SL8500: https://mosemp.us.oracle.com/epmos/faces/DocumentDisplay?id=1305969.1
SL3000: https://mosemp.us.oracle.com/epmos/faces/DocumentDisplay?id=1355485.1
|