Symptoms
Changes
Cause
Solution


Created from <SR 3-16703292231>

Applies to:

Oracle Communications EAGLE (Hardware) - Version EAGLE 46.3 and later
Information in this document applies to any platform.

Symptoms

ERROR
-----------------------

rtrv-ls:lsn=lsnname

stp 18-01-22 14:22:33 IST EAGLE 46.3.0.0.2-68.28.0
rtrv-ls:lsn=lsname
Command entered at terminal #24.
;

Searching link set table on disk - please wait...
Command Accepted - Processing
stp 18-01-22 14:22:33 IST EAGLE 46.3.0.0.2-68.28.0

L3T SLT GWS GWS GWS
LSN APCN (SS7) SCRN SET SET BEI LST LNKS ACT MES DIS SLSCI NIS
lsnname s-1234 none 1 2 no A 1 off off off no off

SPCN CLLI TFATCABMLQ MTPRSE ASL8 GSMSCRN
s-5678 abcdefap 1 --- --- off

SLSRSB RANDSLS ITUTFR ICNIMAP OGNIMAP
1 off off itun2ituns ituns2itun

IPSG IPGWAPC GTTMODE CGGTMOD PCT CHGMTP3OPC
no no SysDflt no off on

L2T PCR PCR E1 E1
LOC LINK SLC TYPE SET BPS ECM N1 N2 LOC PORT TS
1207 B 0 LIME1 26 1.984M BASIC ---- ------ 1207 2 1 <---------1207 B link is present

Link set table is (202 of 1024) 20% full.

;
Command Executed
> rept-stat-card:loc=1207

stp 18-01-22 14:23:05 IST EAGLE 46.3.0.0.2-68.28.0
rept-stat-card:loc=1207
Command entered at terminal #24.
;

Command Accepted - Processing
stp 18-01-22 14:23:05 IST EAGLE 46.3.0.0.2-68.28.0
CARD VERSION TYPE GPL PST SST AST
1207 138-028-000 LIME1 SS7HC IS-NR Active -----
ALARM STATUS = No Alarms.
BLIXP GPL version = 138-028-000
IMT BUS A = Conn
IMT BUS B = Conn
CURRENT TEMPERATURE = 42C (108F)
PEAK TEMPERATURE: = 49C (121F) [18-01-19 21:20]
SIGNALING LINK STATUS
SLK PST LS CLLI
A IS-NR lsnname cliname <<====== there is no B link present here only A link is present

Command Completed.
;
Command Executed
> dact-slk:loc=1207:port=b

stp 18-01-22 14:25:04 IST EAGLE 46.3.0.0.2-68.28.0
dact-slk:loc=1207:port=b
Command entered at terminal #24.
;

E2373 Cmd Rej: Link is unequipped in the database <<============ Unable to delete the link
> rept-stat-e1:e1port=2:loc=1207

stp 18-01-22 14:25:20 IST EAGLE 46.3.0.0.2-68.28.0
rept-stat-e1:e1port=2:loc=1207
Command entered at terminal #24.
;

Command Accepted - Processing
stp 18-01-22 14:25:20 IST EAGLE 46.3.0.0.2-68.28.0
LOC E1PORT PST SST AST
1207 2 IS-NR Avail -----
ALARM STATUS = No Alarms.
UNAVAIL REASON = --
SLK TS PST SST AST

No signaling links provisioned.

Command Completed.
;
Command Executed
> ent-slk:loc=1207:port=b:e1port=2:slc=0:lsn=u1abcaap

stp 18-01-22 14:25:43 IST EAGLE 46.3.0.0.2-68.28.0
ent-slk:loc=1207:port=b:e1port=2:slc=0:lsn=lsnname
Command entered at terminal #24.
;

stp 18-01-22 14:25:43 IST EAGLE 46.3.0.0.2-68.28.0
ENT-SLK: MASP B - Command Aborted
;
E2133 Cmd Rej: There is a link already assigned to this port <<==== Unable to add the link as well





BUSINESS IMPACT
-----------------------
The issue has the following business impact:
Due to this issue, we are unable to delete or recreate link

Changes

rept-stat-card:loc=1207

stp 18-01-22 14:23:05 IST EAGLE 46.3.0.0.2-68.28.0
rept-stat-card:loc=1207
Command entered at terminal #24.
;

Command Accepted - Processing
stp 18-01-22 14:23:05 IST EAGLE 46.3.0.0.2-68.28.0
CARD VERSION TYPE GPL PST SST AST
1207 138-028-000 LIME1 SS7HC IS-NR Active -----
ALARM STATUS = No Alarms.
BLIXP GPL version = 138-028-000
IMT BUS A = Conn
IMT BUS B = Conn
CURRENT TEMPERATURE = 42C (108F)
PEAK TEMPERATURE: = 49C (121F) [18-01-19 21:20]
SIGNALING LINK STATUS
SLK PST LS CLLI
A IS-NR lsnname cliname <<====== there is no B link present here only A link is present

Command Completed.

 

------------------------------------------------------------------------------------------------------------
, but the details of it was not getting removed from the from the rtrv-ls db for that link.

------------------------------------------------------------------------------------------------------------

rtrv-ls:lsn=lsnname
Command entered at terminal #24.
;

Searching link set table on disk - please wait...
Command Accepted - Processing

stp 18-01-22 14:22:33 IST EAGLE 46.3.0.0.2-68.28.0

L3T SLT GWS GWS GWS
LSN APCN (SS7) SCRN SET SET BEI LST LNKS ACT MES DIS SLSCI NIS
lsnname s-1234 none 1 2 no A 1 off off off no off

SPCN CLLI TFATCABMLQ MTPRSE ASL8 GSMSCRN
s-5678 abcdefap 1 --- --- off

SLSRSB RANDSLS ITUTFR ICNIMAP OGNIMAP
1 off off itun2ituns ituns2itun

IPSG IPGWAPC GTTMODE CGGTMOD PCT CHGMTP3OPC
no no SysDflt no off on

L2T PCR PCR E1 E1
LOC LINK SLC TYPE SET BPS ECM N1 N2 LOC PORT TS
1207 B 0 LIME1 26 1.984M BASIC ---- ------ 1207 2 1 <---------1207 B link is present

Link set table is (202 of 1024) 20% full.

 

Cause

There is a memory area on the MASP to store the status of device elements for particular link(s).
Due to some problem(we don't know exactly what is the trigger) , that memory for that linkset was not/improperly allocated.
This was causing the link status to be wrongly displayed.
 

Solution

 This issue should resolve by rebooting both the MASPs (either one by one by issuing command

init-card:loc=< MASP loc>

OR

Rebooting both MASPs together by issuing command

init-card:appl=oam

 