![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2372723.1 : VSM6: email alert message "event.NotifierFailedEvent.dts.description
In this Document
Created from <SR 3-16866211984> Applies to:StorageTek Virtual Storage Manager System 6 (VSM6) - Version All Versions and laterStorageTek Service Delivery Platform (SDP2) - Version 2.2.0 and later Information in this document applies to any platform. SymptomsVSM6 is sending customer email alert message "event.NotifierFailedEvent.dts.description". Site : xxxxxxxxxx Description: SFB cam event log file will show the following message: 2018-02-28 16:10:22 110698 vsmpriv1 (FMS) System NotifierFailedEvent
No problems found with VSM6 healthcheck Changesnone CauseSDP2 failed to respond to Heartbeat response SolutionUpgrade SDP2 to version 2.4 or later, and or VSM6 code to 7.1.1.01 or later which removes CAM Reference <Document 1014070.1> for more information about the VOP/SDP2 2.4
Attachments This solution has no attachment |
||||||||||||||||||||
|