Asset ID: |
1-72-2368794.1 |
Update Date: | 2018-03-05 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2368794.1
:
T10000B - Read Write Errors On Tape Drive, FSC 395e 3965 3961 3517
Related Items |
- Sun StorageTek T10000B Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-16991393559>
Applies to:
Sun StorageTek T10000B Tape Drive - Version All Versions and later
Information in this document applies to any platform.
Symptoms
Read-write errors on different tape media with drive.
2018-03-02 10:24:41 Investigate Drive
HW Address: 1.1.-1.1.3
Total EWI Count for 1.1.-1.1.3: 18
Error Reason(s):
Warning Reason(s): failures_on_multiple_media
Drive Serial: 572004012379
Drive Type: T10000b
Drive Tray Serial: unknown
Bay: Drive_Bay55
HLI Address: X.0.1.6
Vendor: StorageTek
Partition ID: N/A
EWI Messages:
Drive_Bay55(1.1.-1.1.3)
1320 - (1X)
Drive communication time-out 1,1,-1,1,3
(Errors Started - 2018-03-02 10:25:37 Errors Stopped - 2018-03-02 10:25:37)
3842 - (9X)
Drive needs cleaning, drive=1,1,-1,1,3 requester=hli0
(Errors Started - 2018-02-25 09:17:05 Errors Stopped - 2018-03-01 20:11:39)
3992 - (5X)
Warning from device, drive 1,1,-1,1,3: rewindUnload Successful with mediaError: , FSC: 395E
Warning from device, drive 1,1,-1,1,3: rewindUnload Successful with mediaError: , FSC: 395B
VOLSERS seen in 3992 messages: TV0008T1 (x1) TV0009T1 (x1) TV0024T1 (x1) TV0031T1 (x1) TV0089T1 (x1)
(Errors Started - 2018-02-26 18:47:23 Errors Stopped - 2018-03-01 21:46:40)
3993 - (1X)
Device added, device=drive
(Errors Started - 2018-03-02 10:29:19 Errors Stopped - 2018-03-02 10:29:19)
4064 - (1X)
Info message: Drive tray Serial Number needs to be updated, device=drive
(Errors Started - 2018-03-02 10:29:20 Errors Stopped - 2018-03-02 10:29:20)
2018-03-02 10:24:41 Drives with failures from multiple pieces of media:
1.1.-1.1.3 - Volumes: TV0009T1 , TV0089T1 , TV0031T1 , TV0008T1 , TV0024T1
Last message seen: 2018-03-01 21:46:40
This drive is showing excessive perm errors on multiple tapes in the last couple of days.
VOLSER FSC1 FSC2 FSC3 FSC4 HLU_BID LP WRAP
TV0009 395e 3965 3961 3517 0 e97f 0b
TV0089 395e 393a 3961 3517 0 cf5d 1c
TV0031 395e 395e 3961 3517 0 1667 03
TV0008 395b 395e 3961 3517 0 f155 12
TV0024 395b 395e 3961 3517 0 ae7f 12
FSC Perm Error Trace Summary
Total Perm Errors Processed: 58
Total Perm Errors After Filtering: 5
Total Lines Processed : 139
All Tapes Processed: 34
All Tapes Processed(unique): 20
Filtered Tapes Processed: 5
Filtered Tapes Processed (unique): 4
Changes
Cause
Permanent write errors.
Solution
Replace tape drive.
Attachments
This solution has no attachment