![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2368259.1 : SL150 - Message - "Error : Firefox Can Not Establish a Connection to Server" Seen In The Library Console While Initiating Firmware Upgrade
In this Document
Created from <SR 3-16909389712> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. The proposed fix to this issue was to upgrade the firmware from the current build of 0260 to 0320. But the system crashes with the same errors as above while initiating the firmware upgrade. This happens at the upload stage. Also attempted to upgrade using version 0300. It also fails with the same error. SymptomsFirmware upgrade fails as the web console crash. Issue with a repeated interface and login message where the Console would become unresponsive/unavailable with the message : error:Unable to Connect. Firefox can't establish a connection to server 127.x.x.x on the op panel of the SL150 The web interface has "Site can't be reached" error. Tried the same with latest versions of all the browsers IE , Firefox and Chrome but the error is same. Changes
CauseSuspecting the KLC = The Library Controller card located in the robotics CRU. for the op panel issue. Solution1. Replace the robot Attachments This solution has no attachment |
||||||||||||||||||
|