Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2368053.1
Update Date:2018-03-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  2368053.1 :   Cannot Boot due to SMF-8000-MY  


Related Items
  • Sun Netra T5440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5xx0
  •  




Created from <SR 3-16821323897>

Applies to:

Sun Netra T5440 Server - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Boot device: /pci@400/pci@0/pci@8/scsi@0/disk@0:a File and args: -m milestone=none
SunOS Release 5.10 Version Generic_142909-17 64-bit
Copyright (c) 1983, 2010, Oracle and/or its affiliates. All rights reserved.

svc.configd: smf(5) database integrity check of:
/etc/svc/repository.db
failed. The database might be damaged or a media error might have prevented it from being verified. Additional information useful to your service provider is in:

/etc/svc/volatile/db_errors

The system will not be able to boot until you have restored a working database. svc.startd(1M) will provide a sulogin(1M) prompt for recovery purposes. The command:

/lib/svc/bin/restore_repository

can be run to restore a backup version of your repository. See http://sun.com/msg/SMF-8000-MY for more information.

 



Cause

It appears that a faulty motherboard caused this problem.

Solution

Motherboard replacement resolved this problem.
 

References

<NOTE:1331963.1> - Sun SPARC Enterprise T5440 Current Product Issues
<NOTE:1331970.1> - SPARC Enterprise T5440 Firmware and Patches
<NOTE:1543136.2> - My Oracle Support How to: How to enable Service Request Email Update Notification with SR content
<NOTE:166650.1> - Working Effectively With Oracle Support - Best Practices
<NOTE:1588459.1> - Quick User Guide to Upload Files to My Oracle Support - MOS

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback