Solution Type  Problem Resolution Sure

Solution  2367888.1 :   **Can Not Access Sefos  


Related Items
  • Oracle Switch ES1-24
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Ethernet Switches
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-15707432371>

Applies to:

Oracle Switch ES1-24 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Can not get into sefos from the ILOM prompt on two ES1-24 switches that were removed and redeployed from an PCA rack.
Both switches are  otherwise functioning normally, but showed around 90% CPU utilization.

-> cd /SYS/fs_cli
cd: Connecting to Fabric Switch CLI

% Incorrect Login/Password
Oracle ES1-24 login: Never got SEFOS prompt after sending username and
password, 1:TIMEOUT
cd: The session with /SYS/fs_cli has ended.

Changes

 The switches were removed form an OVCA/PCA rack and redployed as stand alone.  The Customer had both inband and out of band ILOM network configured.

Cause

The ES1-24 switches were  were not set to factory default before re deploying as stand alone pair.    As a result the Customer had conflicting ILOM  OOB and Inband network settings.

Solution

Removed inband ILOM settings and rebooted the switch.


-> set /SP/inband_network state=disabled
Set 'state' to 'disabled'

-> show /SP/inband_network  <----------------------------------Confirm

 /SP/inband_network
    Targets:
        test

    Properties:
        commitpending = (Cannot show property)
        dhcp_server_ip = none
        ipaddress = 192.168.4.201
        ipdiscovery = static
        ipgateway = 0.0.0.0
        ipnetmask = 255.255.255.0
        macaddress = 00:10:E0:2F:65:C1
        pendingipaddress = 0.0.0.0
        pendingipdiscovery = static
        pendingipgateway = 0.0.0.0
        pendingipnetmask = 255.255.255.0
        pendingvlanid = 1
        state = disabled <--------------------------------------------------------
        vlanid = 1


-> reset /SP <------------------------------------------------Reboot
Are you sure you want to reset /SP (y/n)?y

 

 

-> cd /SYS/fs_cli<------------------------------------------Verify that the issue is resolved
cd: Connecting to Fabric Switch CLI


SEFOS#  <--------------------------------------------------------Now we can get to the SEFOS prompt

 

References

<BUG:26773049> - ES1-24 DOES NOT ALLOW ACCESS TO SEFOS ON TWO SWITCHES.