Created from <SR 3-16799371651> Applies to:Oracle ZFS Storage ZS4-4 - Version All Versions to All Versions [Release All Releases]Oracle ZFS Storage ZS5-2 - Version All Versions to All Versions [Release All Releases] Oracle ZFS Storage ZS5-4 - Version All Versions to All Versions [Release All Releases] 7000 Appliance OS (Fishworks) SymptomsUnder the BUI, you cannot see a Meta device but can only see the device as a Data Drive.
ChangesAdded Meta SSD.
CauseIncorrect part installed. SolutionThe SSD part number fitted is only qualified for the FS1 disk array and not the DE3-24 JBOD storage. Please check that you have not fitted a HBTAC2DH2SUN3.2T = 7350500 [C]
There are two types of ZFS DE3 part number and you want 7337005 [C], which is HBCAC2DH2SUN3.2T
The device part number is used to determine whether the device is a Data drive or a Meta device. References<NOTE:2340720.1> - Resilvering a Device in a ZFS Pool may Result in checksum Errors and Possible Data Integrity Issues<NOTE:2316083.1> - Support Strategy for Replacing a 200GB SSD in SPARC Based Systems Attachments This solution has no attachment |
||||||||||||||||||||
|