Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2365691.1
Update Date:2018-04-27
Keywords:

Solution Type  Problem Resolution Sure

Solution  2365691.1 :   Oracle ZFS Storage Appliance: How to resolve a Meta Read SSD being seen as a Data Drive when being added to a Pool  


Related Items
  • Oracle ZFS Storage ZS5-4
  •  
  • Oracle ZFS Storage ZS5-2
  •  
  • Oracle ZFS Storage ZS4-4
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: ZS
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-16799371651>

Applies to:

Oracle ZFS Storage ZS4-4 - Version All Versions to All Versions [Release All Releases]
Oracle ZFS Storage ZS5-2 - Version All Versions to All Versions [Release All Releases]
Oracle ZFS Storage ZS5-4 - Version All Versions to All Versions [Release All Releases]
7000 Appliance OS (Fishworks)

Symptoms

Under the BUI, you cannot see a Meta device but can only see the device as a Data Drive.

 

Changes

Added Meta SSD.

 

Cause

Incorrect part installed.

Solution

The SSD part number fitted is only qualified for the FS1 disk array and not the DE3-24 JBOD storage.

Please check that you have not fitted a HBTAC2DH2SUN3.2T  = 7350500 [C]

 

There are two types of ZFS DE3 part number and you want 7337005 [C], which is HBCAC2DH2SUN3.2T

 

The device part number is used to determine whether the device is a Data drive or a Meta device.

References

<NOTE:2340720.1> - Resilvering a Device in a ZFS Pool may Result in checksum Errors and Possible Data Integrity Issues
<NOTE:2316083.1> - Support Strategy for Replacing a 200GB SSD in SPARC Based Systems

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.