Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2364715.1
Update Date:2018-02-26
Keywords:

Solution Type  Problem Resolution Sure

Solution  2364715.1 :   T10000D - Readback Error Was Detected During A Write Operation, FSC 391A  


Related Items
  • StorageTek T10000D Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: Remote
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-16813883771>

Applies to:

StorageTek T10000D Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Summary:A readback error was detected during a write operation.

Fault event description:A readback error was detected during a write operation.
receiver_id: SDP2-2.4
siteID: 1390996372442.0
A readback error was detected during a write operation.
************* ADDITIONAL INFORMATION *************
*** Alarm Description ***
FSC(391A): A readback error was detected during a write operation.
A readback error was detected during a write operation.
Device Dmod: 579004005203
Tray SN: 464970G+1537J91090
Device Model: T10000D
Trap Type: tapenewpermlog
Locator Text: ACS/LSM/Pnl/Drv: 0/0/0/0, Library: SL8500 : stklmu, Drive Location: 1,4,-2,1,4, Mfg S/N: 579004005203, Tray S/N: unknown, Request ID: 0x00000000009ECB91

Changes

 

Cause

FSC: 391A RO_FSC_WRT_MATRIX_Q_SEQ_ERROR
MIM Code: NONE

FRU: MEDIA CONF: 50%
FRU: HARDWARE CONF: 49%
FRU: MICROCODE CONF: 1%.......Make sure the drive is latest code

Solution

According to log analysis the seems to be failed with the bad media :

Inspect the bad media : G09921

Power cycle the drive from SLC and run the test backup with the known tape and confirm the status.

 

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.