![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2364635.1 : T10000D - Volsafe Tapes Are Write Inhibited - 4020 Errors
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:StorageTek T10000D Tape Drive - Version All Versions and laterInformation in this document applies to any platform. SymptomsVolsafe tapes are being set to write inhibited by the application when 4.13.101 microcode was installed. FSC 4020, FSC4020 Changes
CauseThere was a code change in 4.13.101 code that brought out the problem. FSC Dictionary Description: Engineering Text: SolutionDowngrade the microcode to 4.12.106 version and wait for the next code release which will have the fix in it. A special build can be requested by any customer that cannot downgraded to 4.12.106 code. Attachments This solution has no attachment |
||||||||||||||||||
|