Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2364635.1
Update Date:2018-02-26
Keywords:

Solution Type  Problem Resolution Sure

Solution  2364635.1 :   T10000D - Volsafe Tapes Are Write Inhibited - 4020 Errors  


Related Items
  • StorageTek T10000D Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel

Applies to:

StorageTek T10000D Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Volsafe tapes are being set to write inhibited by the application when 4.13.101 microcode was installed.

FSC 4020, FSC4020

Changes

 

Cause

There was a code change in 4.13.101 code that brought out the problem.

FSC Dictionary Description:
MODEL = T10000D
FSC = 4020
(FSC Match Found in Rev. 4.13)

FSC: 4020 RO_FSC_VOLSAFE_WRT_MIR_INCOMPLETE
MIM Code: NONE
FRU: STATUS ONLY CONF: 100%
Summary: |INFORMATION |ONLY | *** |
Field Text:
Volsafe write was attempted on a tape with an incomplete MIR.

Engineering Text:
Volsafe appends are allowed only in tapes with complete MIR. The tape was found to have an incomplete MIR and hence volsafe append rejected. The error was found in the function ro_evaluate_pos_for_volsafe_wrt.

Solution

 Downgrade the microcode to 4.12.106 version and wait for the next code release which will have the fix in it. A special build can be requested by any customer that cannot downgraded to 4.12.106 code.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.