![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2362620.1 : SL150 - Bridge Drive Lost Connection, All Drives In Fault Status, USB HUB reset
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsSL150 Tape Library show failed, bridge drive lost connection, all drives in faulty status. Sample of events: 0.0.0.0.0, 000, tti-dbg, , warn, 0000, 0000, "ADT: receive: Called but nothing to read!! Drive: 1" 0.0.0.0.0, 000, tti-dbg, , warn, 0000, 0000, "ADT: sendPkt: Drive: 1 - Was logged out, had to renegotiate the link!" USB HUB reset ChangesAfter robot replacement. CausePreviously replaced robot is defective. Error is seen after robot replacement. Bug 24704615: USB: LUN Communication Timeout during cartridge move test" @ Planned Hardware Fixes to prevent most USB communication faults (EMI
SolutionFor these 2 EC's, the only robot that has these 2 ECs implemented is part number 7332809 which is the new long robot for the SL150e. The higher P/N 7333965 robot actually does not have the EC implemented because it was released before the long robot was released. If you have a USB HUB reset then the 7332809 would be the only recommended robot at this time. In the next month or two they are going to be releasing a new robot P/N that will contain 2 more ECs that are meant to help with the USB HUB reset issues. References<NOTE:2330233.1> - SL150 - DRIVE_COMM_FAILURE - Fault Code:9020Attachments This solution has no attachment |
||||||||||||||||||||
|