Solution Type Problem Resolution Sure Solution 2362113.1 : VSM6 - IDR1626.1 Installation (can induce panic in VSM7)
Created from <SR 3-16644496691> Applies to:StorageTek Virtual Storage Manager System 6 (VSM6) - Version All Versions and laterStorageTek Virtual Storage Manager System 7 (VSM7) - Version 7.0.0 to 7.1.2 [Release 7.0] Information in this document applies to any platform. SymptomsVSM6 or VSM7 panic during the installation of IDR1626.1 on another VSM6 connected to the same FICON infrastructure. ChangesIDR1626.1 is being installed on a VSM6. Cause There is a point in the VSM6 installation of IDR1626.1 where the machine does not know it is a VSM6. SolutionWorkaround: Completely isolate the VSM6 being upgraded with IDR1626.1 from the FICON infrastructure.
Fix: This problem is addressed in version 7.1.2.05.000 and higher levels of VSM6 and VSM7 code. References<BUG:27387024> - NODE KERNEL PANIC AND REBOOT - SUNOS-8000-KLAttachments This solution has no attachment |
||||||||||||
|